HP XP7 Business Continuity Manager Reference Guide (TK954-96004)

Table 150 Device Information Structure (continued)
DescriptionREXX variables
Consistency time acquired in accordance with
the storage system's system option mode (TOD
or disk controller time)
TIME
Consistency time acquired from the journal (TOD
or disk controller time)
JNL_TIME
Consistency time acquired from the volume (TOD
or disk controller time)
SVOL_TIME
Existence of inter-CU path information (Valid)Info
1
CUxxPath
Number of inter-CU logical paths established from
the CU to which this device belongs (0 to 4)
0
Path typetypen
ESCON
FIBRE
Model of secondary storage systemModelSec
USP (XP12000/XP10000)
USPV (XP24000/XP20000)
VSP (XP P9500)
VSPG1000 (XP7)
Serial number of secondary storage systemSerialnum
SSID1 of secondary storage systemSSID1
SSID2 of secondary storage systemSSID2
SSID3 of secondary storage systemSSID3
SSID4 of secondary storage systemSSID4
Number of physical paths in inter-CU logical path
(0 to 8)
0P2S
Status of physical pathStatusn
NO PATH
ESTABLISHED
INIT FAILED
TIME OUT
NO RESOURCES AT PRI
NO RESOURCES AT SEC
SERIAL# MISMATCH
CONFIG ERROR
Initiator port number (for ESCON, link address)Pri.Port
Target port number (for ESCON, link address)Sec.Port
Secondary CU numberSec.CUNum
Existence of inter-DKC path information (Valid)Info
1
DKC
Model of secondary storage systemModelSec
USP (XP12000/XP10000)
USPV (XP24000/XP20000)
About REXX Variable Structures 345