HP XP7 RAID Manager Installation and Configuration User Guide (T1610-96065)
Table Of Contents
- XP7 RAID Manager Installation and Configuration User Guide
- Contents
- 1 Installation requirements
- System requirements
- Supported environments
- Supported Business Copy environments
- Supported Continuous Access Synchronous environments
- Supported Continuous Access Asynchronous environments
- Supported Continuous Access Journal environments
- Supported Snapshot environments
- Supported Data Retention environments
- Supported Database Validator environments
- Supported guest OS for VM
- Supported IPv4, IPv6 platforms
- Requirements and restrictions for z/Linux
- Requirements and restrictions for VM
- Porting notice for OpenVMS
- Using RAID Manager with Hitachi and other storage systems
- 2 Installing and configuring RAID Manager
- 3 Upgrading RAID Manager
- 4 Removing RAID Manager
- 5 Troubleshooting
- 6 Support and other resources
- A Fibre-to-SCSI address conversion
- B Sample configuration definition files
- Glossary
- Index
For Windows:set HORCMINST=0 set HORCC_MRCF=1
• Designate a group name (Oradb) and a local instance P- VOL a case.
# paircreate -g Oradb -vl
# paircreate -g Oradb1 -vr
These commands create pairs for all LUs assigned to groups Oradb and Oradb1 in the configuration
definition file.
• Designate a group name and display pair status.
# pairdisplay -g oradb -m cas
Group PairVol(L/R) (Port#,TID,LU-M), Seq#, LDEV#. P/S, Status, Seq#, P-LDEV# M
oradb oradev1(L) (CL1-A , 1, 1-0) 30053 266.. P-VOL PAIR, 30053 268 -
oradb oradev1(R) (CL1-D , 2, 1-0) 30053 268.. S-VOL PAIR, ----- 266 -
oradb1 oradev11(R) (CL1-D , 2, 1-1) 30053 268.. P-VOL PAIR, 30053 270 -
oradb2 oradev21(R) (CL1-D , 2, 1-2) 30053 268.. SMPL ----, ----- ---- -
oradb oradev2(L) (CL1-A , 1, 2-0) 30053 267.. P-VOL PAIR, 30053 269 -
oradb oradev2(R) (CL1-D , 2, 2-0) 30053 269.. S-VOL PAIR, ----- 267 -
oradb1 oradev12(R) (CL1-D , 2, 2-1) 30053 269.. P-VOL PAIR, 30053 271 -
oradb2 oradev22(R) (CL1-D , 2, 2-2) 30053 269.. SMPL ----, ----- ---- -
Example of RAID Manager commands with Instance-1 on HOSTA:
• When the command execution environment is not set, set an instance number.
For C shell:# setenv HORCMINST 1 # setenv HORCC_MRCF 1
For Windows:set HORCMINST=1 set HORCC_MRCF=1
• Designate a group name and a remote instance P-VOL a case.
# paircreate -g Oradb -vr
# paircreate -g Oradb1 -vl
These commands create pairs for all LUs assigned to groups Oradb and Oradb1 in the configuration
definition file.
• Designate a group name and display pair status.
# pairdisplay -g oradb -m cas
Group PairVol(L/R) (Port#,TID,LU-M),Seq#,LDEV#.P/S,Status, Seq#,P-LDEV#
M
oradb oradev1(L) (CL1-D , 2, 1-0)30053 268..S-VOL PAIR,----- 266
-
oradb1 oradev11(L) (CL1-D , 2, 1-1)30053 268..P-VOL PAIR,30053 270
-
oradb2 oradev21(L) (CL1-D , 2, 1-2)30053 268..SMPL ----,----- ----
-
oradb oradev1(R) (CL1-A , 1, 1-0)30053 266..P-VOL PAIR,30053 268
-
oradb oradev2(L) (CL1-D , 2, 2-0)30053 269..S-VOL PAIR,----- 267
-
oradb1 oradev12(L) (CL1-D , 2, 2-1)30053 269..P-VOL PAIR,30053 271
-
oradb2 oradev22(L) (CL1-D , 2, 2-2)30053 269..SMPL ----,----- ----
-
oradb oradev2(R) (CL1-A , 1, 2-0)30053 267..P-VOL PAIR,30053 269
-
The command device is defined using the system raw device name (character-type device file
name). The command device defined in the configuration definition file must be established in a
way to be following either every instance. If one command device is used between different
instances on the same SCSI port, then the number of instances is up to 16 per command device.
84 Sample configuration definition files