HP XP7 RAID Manager Reference Guide (T1610-96064)

raidcom add journal
Registers (adds) a volume to a journal.
This makes a Journal for "Open System" or "M/F System" to the specified LDEVs.
If the journal already exists, the specified LDEV is added to the journal.
If the journal does not exist, you must create it first, and then add an LDEV.
If the -timer_type option is specified, this command makes a journal as "M/F System". If not, this
command makes a journal as "Open System".
A device group can also be specified instead of an LDEV.
This command is executed asynchronously with the command input. Check the completion of this
process on the raidcom get command_status command.
Syntax
raidcom add journal -journal_id <journal ID#> {-ldev_id <ldev#>
[-cnt <count>] | -grp_opt <group option>
-device_grp_name <device group name> [<device name>]}
[-mp_blade_id <mp#> | -timer_type <timer type> ]
Options and parameters
DescriptionOption
Specifies the journal number (0-255).-journal_id <journal ID#>
Specifies the LDEV number (0-65279).-ldev_id <ldev#>
Up to 64 LDEVs can be specified at a time. For example:
-ldev_id 200
-ldev_id 100-110
-ldev_id 100 -cnt 10
Specifies the count (2-64).[-cnt <count> ]
If this option is omitted, "1" is used as the count.
Specifies the device information extracted from the LDEV belonging to the device
group.Specify "ldev" (fixed). The information of LDEV belonging to the device group is
used.
-grp_opt <group option>
Specifies the name of device group (maximum 32 characters) to be operated.-device_grp_name <device
group name> [<device
name>]
To operate an LDEV in the device group, specify the device name of LDEV (maximum 32
characters) within the device group.
If the device name is omitted, all of the LDEVs belonging in the device group are operated.
Specifies the MP blade ID number (0-7).[-mp_blade_id <mp#> ]
If this option is omitted, the device automatically allocates an MP blade ID number. For
example:
-mp_blade_id 2
Specifies the timer type: system, local, or None. For example:[-timer_type <timer type> ]
-timer_type system
-timer_type local
For details, see the Continuous Access Journal manual for the storage system.
Examples
Examples for Open:
raidcom add journal 155