HP XP7 RAID Manager Reference Guide (T1610-96064)

P_NO: Displays the partition number partitioning this Parity Group.
LDEV#: Displays LDEV number.
STS: Displays the following status.
NML: LDEV is installed or free space is settled.
REG: LDEV is being created.
DEL: LDEV is being deleted.
LOC_LBA: Displays the Start of LBA for this partition on this Parity Group, in units of 512 bytes.
SIZE_LBA: Displays the size for this partition on this Parity Group, in units of 512 bytes.
Serial#: Product serial number.
For XP7 Storage, the number of which 300,000 is added to the serial number is displayed.
raidcom add rcu
Registers RCUs.
This command is executed asynchronously with the command input. Check the completion of this
process on the raidcom get command_status command.
Syntax
raidcom add rcu {-rcu <serial#> <mcu#> <rcu#> <id> -ssid <ssid>
| -cu_free <serial#> <id> <pid> -mcu_port <port#>
-rcu_port <port#>
Options and parameters
DescriptionOption
Specifies the CU specified by serial number, <mcu#>, <rcu#>, and <id>. For XP7 Storage,
specify the number of which 300,000 is added to the serial number for <serial#>. You
-rcu <serial#> <mcu#>
<rcu#> <id>
can use hexadecimal numbers (add "0x" prefix) or decimal numbers for <mcu#> and
<rcu#>.
< id > specifies the storage system type as follows:
For XP7 use R800.
For P9500 use R700.
For XP24000/XP20000 Disk Array use R600.
For XP12000 Disk Array/XP10000 Disk Array use R500.
Specifies subsystem IDs. Up to 4 SSIDs can be specified.-ssid <ssid>
You can use hexadecimal numbers (add "0x" prefix) or decimal numbers for <ssid>.
Specifies the CU free specified by serial#, id#, pid#. For XP7 Storage, specify the number
of which 300,000 is added to the serial number for <serial#>.
-cu_free <serial#> <id>
<pid>
< id > specifies the storage system type as follows:
For XP7 use R800.
For P9500 use R700.
For XP24000/XP20000 Disk Array use R600.
For XP12000 Disk Array/XP10000 Disk Array use R500.
< pid> specifies the path group ID (0-255).
Note:
The RCU registered by specifying "0" for <pid> is displayed by default or "0" on
the GUI of Continuous Access Synchronous, Continuous Access Journal, or Continuous
Access Journal Z.
194 Configuration setting commands