HP XP7 RAID Manager User Guide (T1610-96063)

Table 81 SSB codes returned by raidcom add snapshot (continued)
raidcom add snapshot
DescriptionError codeExecuting/AsyncError message
SSB2SSB1
A Fast Snap or Snapshot pair cannot be created because
the Thin Provisioning V-VOL in capacity expanding is
specified as the P-VOL of a Fast Snap or Snapshot pair.
00412E10ExecutingCMDRJE
A Fast Snap or Snapshot pair cannot be created because
the Thin Provisioning V-VOL that is discharging zero data
is specified as the P-VOL of a Fast Snap or Snapshot pair.
00422E10ExecutingCMDRJE
A pair cannot be created because the P-VOL of a
Continuous Access Synchronous pair is specified as the
S-VOL of a Fast Snap or Snapshot pair.
00452E10ExecutingCMDRJE
A pair cannot be created because the S-VOL of a
Continuous Access Synchronous pair is specified as the
S-VOL of a Fast Snap or Snapshot pair.
00462E10ExecutingCMDRJE
The command ends abnormally because the Business Copy
pair is being resynchronized when the volume is shared
00492E10ExecutingCMDRJE
between the P-VOL of a Fast Snap/Snapshot pair and the
P-VOL of a Business Copy pair.
The command ends abnormally because the Business Copy
pair status is other than PSUS when the volume is shared
004A2E10ExecutingCMDRJE
between P-VOL of a Fast Snap/Snapshot pair and the
S-VOL of a Business Copy pair.
The operation cannot be performed because the Quick
Restore is being operated on the specified Business Copy
P-VOL.
004E2E10ExecutingCMDRJE
A pair operations cannot be performed because the volume
using 2 mirrors included in the 3DC multi-target
00512E10ExecutingCMDRJE
configuration, 3DC cascade configuration or 3DC delta
resync configuration by the 3 Continuous Access Journal
sites is specified.
A Fast Snap pair cannot be created because the pair status
of all Fast Snap pairs sharing the specified P-VOL is PSUE.
00522E10ExecutingCMDRJE
A Fast Snap pair cannot be operated because the virtual
storage machine of the P-VOL is different from the virtual
storage machine of the S-VOL.
005B2E10ExecutingCMDRJE
A Fast Snap pair cannot be operated because changing
the model and the serial number in the virtual storage
machine of the specified P-VOL is in progress.
005C2E10ExecutingCMDRJE
A Fast Snap pair cannot be operated because changing
the model and the serial number in the virtual storage
machine of the specified S-VOL is in progress.
005D2E10ExecutingCMDRJE
A Fast Snap or Snapshot pair with the specified consistency
group number cannot be created due to one of the
following reasons:
23002E10ExecutingCMDRJE
The specified consistency group number is used by the
Business Copy.
The number of pairs that can be defined in a consistency
group exceeds the maximum.
The pair created by using the same P-VOL already exists
in the specified consistency group.
264 Troubleshooting