HP XP7 Remote Web Console Messages (H6F56-96010)

Table 56 Error codes (part code 06005) (continued)
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
retry the operation. If the volume is connected to
a VM system, vary the volume offline from the VM
system.
WVerify the emulation type of the remote storage
system.
The emulation type of the remote storage
system does not support Continuous
00875106005
Access Synchronous or Continuous
Access Synchronous Z.
EToo many pairs might be specified. Verify the
pairs whose statuses are unchanged from those
An internal error occurred.00875306005
before the operation, reduce the number of pairs
to be specified, and then retry the operation on
the pairs. If this problem persists, contact HP
Technical Support.
WVerify the serial number or SSID of the local
storage system, and then retry the operation with
the correct parameter.
The serial number or SSID of the local
storage volume is invalid.
00875406005
WVerify the cache status of the storage system
connected to the host. If the cache is disabled,
The cache of the local storage system is
not active.
00875606005
enable the cache. If you cannot enable the cache,
contact HP Technical Support.
EVerify the status of the cache and the shared
memory in the local storage system, and then
contact HP Technical Support.
One side of the cache or the shared
memory is blocked in the local storage
system.
00875706005
EContact HP Technical Support.An unexpected error occurred in the
local storage system.
00875806005
WVerify the cache status of the local storage system
connected to the host. If the cache is disabled,
The cache of the remote storage system
is not active.
00875906005
enable the cache. If you cannot enable the cache,
contact HP Technical Support.
WVerify the emulation types of the specified primary
and secondary volumes.
The primary and secondary volume track
formats do not match.
00876006005
WSpecify a different volume for the primary volume
or the secondary volume.
The operation cannot be performed due
to one of the following reasons:
00876106005
The emulation types of the primary
and secondary volumes do not
match.
The capacities of the primary and
secondary volumes do not match.
The secondary volume is a LUSE
volume.
WVerify the cache status of the secondary volume
connected to the host. If the cache is disabled,
The cache of the secondary volume is
not active.
00876206005
enable the cache. If you cannot enable the cache,
contact HP Support Center.
WVerify the DFW status of the secondary volume
connected to the host. If the DFW is disabled,
The DFW status of the secondary volume
is not active.
00876306005
enable the DFW. If you cannot enable the DFW,
contact HP Technical Support.
WVerify the status of the specified secondary
volume.
The specified secondary volume cannot
be used.
00876406005
152 Message (part code group 06nnn)