Hitachi Global Link Manager Software Installation and Configuration Guide
Item Description
• Warning: 4
• Information: 6
Specifiable value: 0 to 7 (Severity)
Default: 6
The table below shows the correspondence between the severity levels of
audit events and the types of event log data.
Table 3-20 Correspondence Between the Severity Levels of Audit Events
and the Types of Event Log Data
Severity of Audit Events Type of Event Log Data
0 Error
1
2
3
4 Warning
5 Information
6
7
The following shows an example of the auditlog.conf file:
# Specify an integer for Facility. (specifiable range: 1-23)
Log.Facility 1
# Specify the event category.
# You can specify any of the following:
# StartStop, Failure, LinkStatus, ExternalService,
# Authentication, AccessControl, ContentAccess,
# ConfigurationAccess, Maintenance, or AnomalyEvent.
Log.Event.Category Authentication,ConfigurationAccess
# Specify an integer for Severity. (specifiable range: 0-7)
Log.Level 6
In this example, audit logs for the audit events in the Authentication or
ConfigurationAccess category whose type is error, warning, or information
will be output.
Output Format of the Audit Log Files
Audit logs are output to the Windows event log file. This section shows the
format of entries and describes the elements in an entry.
3-68
Setting Up Global Link Manager
Hitachi Global Link Manager Installation and Configuration Guide (Web Version)