HP XP7 Business Continuity Manager Messages (TK954-96003)
Table 45 Business Continuity Manager error messages and corresponding troubleshooting actions
(message ID YKZ41x) (continued)
Explanation and recommended actionsMessage textMessage ID
• Quick suspend mode for the CAJ ATTIME suspend
function
◦ XP24000/XP20000 disk array
Version of the storage system support function:
X'23' or higher
• Path group ID specification for Cnt Ac-J Z
◦ XP P9500
Version of the storage system support function:
X'33' or higher
• Consistency group ID for the Cnt Ac-S Z copy
group that exceeds X'7F'
◦ XP P9500
Version of the storage system support function:
X'40' or higher
The device defined in the disk configuration definition
file exists on a storage system that differs from the
The device indicated by devn in the
disk configuration definition file is on
a storage system that differs from sn.
YKZ415E MSG SC=48
RC=48
storage system in the disk configuration definition
file. For this reason, a NG scan cannot be executed.
Check the device address domain ID specified in the
disk configuration definition file or the Set Defaults
panel. For details about the NG scan, see the HP
XP7 for Business Continuity Manager Reference
Guide.
devn (hexadecimal number)
Device number defined in the disk
configuration definition file
sn
Serial number of the storage
system on which the device
indicated by devn actually exists
This storage system does not allow Cnt Ac-S Z data
differential-data management units to be specified.
Copygroup SUPFnc does not support
CA Map (DIF UNIT).
YKZ416E MSG SC=36
RC=36
1
Use a device
2
that allows Cnt Ac-S Z data
differential-data management units to be specified.
Also, if scanning was not performed after the storage
system microcode was replaced, perform another
scan.
SUPFnc (hexadecimal number)
Value for the version of the
storage system support function
used in the copy group (minimum)
1
If this message is output while the YKLOAD
command is being executed, the RC is 44.
2
Units of Cnt Ac-S Z data differential-data
management units can be specified on storage
164 Messages