HP XP7 Business Continuity Manager Messages (TK954-96003)

<cgsaact>: Startup action executed if the copy pair status for starting BCM Monitor is different
from the specified startup status
<cgsaopt>: Option information of the CGSTARTUPSTATUS parameter
<status> <action><err-action>: Status, action, and error action for the copy group
specified in STATUS and ACTION. These parameters appear a specified number of times.
User completion codes
Table 46 (page 170) provides details about the user completion codes.
Table 46 User completion codes
ExplanationCompletion code
There is a problem with the issued CCW.U0003
The version of the registered user SVC routine might be old. Check whether the latest
user SVC routine is registered by performing one of the following operations:
Using a CLI command:
Execute the YKINSCHK command, and check that OK is displayed for User SVC
Routine.
From the ISPF panel:
From the Installation Verification Summary panel, check that OK is displayed for
User SVC Routine.
The user does not have the permission to execute CLI commands. The user might not
have been given permissions to view the profile required for executing the CLI
command, or an RACF error occurred.
U0128
If a reason code exists, it is displayed in the following format:
XXYYZZZZ:
XX: Lower 1 byte of SAF RC of the RACROUTE macro
YY: Lower 1 byte of RACF RC of the RACROUTE macro
ZZZZ: Lower 2 bytes of RACF Reason Code of the RACROUTE
macro
If the reason code is 00000010 or 00000030:
The user who attempted to execute the command has not been
granted view permissions for the STGADMIN.YKA.BCM.COMMANDS
profile or the STGADMIN.YKA.BCM.YKQUERY profile. Therefore,
the user cannot execute CLI commands to view the operations or
status of copy pairs, paths, or command devices.
If the reason code is 00000040, 00000050, or 00000070:
The user who attempted to execute the command has been granted
only the view permission for the STGADMIN.YKA.BCM.YKQUERY
profile. Therefore, the user cannot execute CLI commands to
operate copy pairs, paths, and command devices.
If the reason code is other than the above:
The information returned from the RACROUTE REQUEST=AUTH
macro is displayed. For details, see the Security Server RACROUTE
Macro Reference.
An attempt was made to call a module that cannot be executed in Business Continuity
Manager. There might be a problem in the LINKLIB library settings. Specify the
Business Continuity Manager installation dataset for the LINKLIB library.
U1009