HP XP7 Business Continuity Manager Messages (TK954-96003)
Table 49 Details of error codes 36xx (continued)
Type of errorError detailsError
code
OthersTHPzPATHCMDCAJCAACABC
Not outputOutputNot outputRegistration to EXCTG has failed
because the specified storage
system model name is invalid.
3685
Not outputOutputNot outputRegistration to EXCTG has failed
because the journal group to be
3686
registered is already registered to
another EXCTG.
Not outputOutputNot outputRegistration to EXCTG has failed
for one of the following reasons:
3688
• The mirror status of the specified
journal group is not Active or
Stop.
• The Disaster Recovery Extended
program product is not installed.
• The specified journal group is
already registered in a CAJ
Open/MF consistency group.
• The specified journal group is
set to be used in 3DC
(CAJxCAJ) configurations.
Not outputOutputNot outputRegistration to EXCTG has failed
because the attribute of the journal
3689
group to be registered is different
from the attribute of the EXCTG.
Not outputOutputNot outputRegistration to EXCTG has failed
because the timer type of the
368A
journal group to be registered is
not System.
Not outputOutputNot outputRegistration to EXCTG has failed
because the combination of the
3694
serial number and device on the
specified arbitration command
device is incorrect.
Not outputOutputNot outputRegistration to EXCTG has failed
because the journal group to be
3695
registered is an open-system journal
group.
Table 50 Details of error codes 37xx
Type of errorError detailsError
code
OthersTHPzPATHCMDCAJCAACABC
Not outputOutputNot outputA CAJ copy pair cannot be
resynchronized (with the
3703
PREPARE parameter) because
the journal volume has PIN data.
Not outputOutputNot outputThe CAJ copy pair cannot be
made because the emulation
3704
type for the specified M-JNL
group does not match that of the
R-JNL group.
184 Storage system sense byte information