HP XP7 Business Continuity Manager Messages (TK954-96003)
Table 56 Details of error codes 7Fxx – 8Cxx
Type of errorError detailsError
code
OthersTHPzPATHCMDCAJCAACABC
OutputNot outputThe command cannot be executed
because no program product for
copying is installed.
7F86
OutputNot outputThis command is not supported.7FD4
OutputNot
output
OutputNot outputOutputNot
output
A CA or CAA copy pair status
cannot be changed. Possible
8C12
reasons include one or more of
the following:
• The specified S-VOL is online.
• The specified volume is either
a CA or CAA pair volume, or
the S-VOL of a BC copy pair.
• All paths to the RCU are
blocked.
• The status of the copy pair is
not possible for the requested
transition (it is possible that it
is already in requested copy
pair status).
• The logical volume of the
specified volume is blocked.
• The path between the primary
site and the secondary site is
in the BUSY status.
• The emulation type of the
P-VOL and the S-VOL do not
match. Alternatively, the
number of cylinders in the
S-VOL is less than the P-VOL.
• Either the status of the P-VOL
is being changed, or there is
a copy pair in the group with
the status being changed.
• The command could not be
executed because the specified
CA or CAA volume is in the
SIMPLEX status.
• The S-VOL is not in the
SWAPPING status.
• Either the status of the P-VOL
is being changed, or there is
a copy pair in the group with
the status being changed.
• A copy pair cannot be made
because the same C/T group
ID is set in both the MCU and
RCU.
• The specified C/T group ID is
not registered.
• Alternatively, a path cannot be
defined and deleted because
either the copy pair status or
the parameter is invalid. (The
possible reasons are
Details of error codes 207