HP XP7 Business Continuity Manager Messages (TK954-96003)

Table 57 Details of error codes 8Dxx (continued)
Type of errorError detailsError
code
OthersTHPzPATHCMDCAJCAACABC
reasons include one or more of
the following:
The S-VOL is online.
The status of the copy pair
does not allow the status
transition. For details, see error
code 2310.
The P-VOL is online.
The charging limit of the
program product was
exceeded.
The copy pair is in the Pending
status.
The copy pair is not in the Split
status.
The specified C/T group ID is
not registered.
The number of copy pairs in
the specified C/T group ID
exceeds the maximum number.
OutputNot outputThe serial numbers for the primary
and the secondary storage
8D1E
systems in the host command
parameter is incorrect.
Not outputOutputThe host command parameter is
incorrect.
8D20
Not outputOutputNot outputThe command cannot be executed
because the volume specified by
8D21
the host command parameter is
in the NOT READY status.
Not outputOutputNot outputThe command cannot be executed
because the logical volume of the
8D22
volume specified by the host
command parameter is blocked.
Not outputOutputThe command could not be
executed because the CA, CAA,
8D25
or BC program product is not
installed.
Not outputOutputA BC copy pair cannot be
suspended. Possible reasons
8D26
include one or more of the
following:
The status of the copy pair
does not allow the status
transition. For details, see error
code 2310.
The copy pair is in the
SIMPLEX status.
The copy pair is in the Split
status.
The specified C/T group ID is
not registered.
Details of error codes 211