HP XP7 Business Continuity Manager Messages (TK954-96003)

Table 62 Details of error codes C3xx (continued)
Type of errorError detailsError
code
OthersTHPzPATHCMDCAJCAACABC
Not outputOutputNot
output
The cache for the MCU is being
blocked on one side (in
C382
transition) or it is being
recovered on one side.
Not outputOutputNot
output
A copy pair cannot be made
because the P-VOL is not
supported for the emulation type.
C388
Not outputOutputNot
output
RCU is already in use by CA or
CAA.
C38B
Not outputOutputNot
output
A CA copy pair cannot be
defined or resynchronized. The
C38D
reason might be one of the
following:
The S-VOL is in an unusable
state.
The microprogram version of
the MCU or RCU does not
support the function or
configuration.
Not outputOutputNot
output
The S-VOL device is not
supported by CA or CAA.
C38E
Not outputOutputNot
output
The S-VOL is not in the suspend
status.
C390
Not outputOutputNot
output
The S-VOL is in a copy pair
status that does not permit
copying.
C391
Not outputOutputNot
output
The S-VOL is online.
Alternatively, a copy pair was
C392
already made for a copy type
other than CA or CAA.
Not outputOutputNot
output
The S-VOL has PIN data.C393
Not outputOutputNot
output
The S-VOL is online.C394
Not outputOutputNot
output
The S-VOL cannot be used
(because of a logical volume
C395
being blocked, collection access,
and so on).
Not outputOutputNot
output
A copy pair cannot be made
because the S-VOL is not
supported for the emulation type.
C398
Not outputOutputNot
output
The P-VOL capacity exceeds the
volume capacity within which a
copy pair can be made.
C39E
Not outputOutputNot
output
The P-VOL or S-VOL capacity
exceeds the volume capacity
C39F
within which a copy pair can be
made.
Not outputOutputNot
output
The P-VOL device is not
supported by CA or CAA.
C3A0
232 Storage system sense byte information