Table 65 Details of error codes EAxx (continued)
Type of errorError detailsError
code
OthersTHPzPATHCMDCAJCAACABC
Not outputOutputNot outputA CAJ copy pair
resynchronization, which
EA22
causes a copy direction
reversal, cannot be made
because the journal group is
not in the Stop status.
Not outputOutputNot outputA CAJ copy pair
resynchronization, which
EA25
causes a copy direction
reversal, cannot be made
because the copy pair is not
in the SWAPPING status.
Not outputOutputNot outputA CAJ copy pair cannot be
dissolved because the M-JNL
EA29
group is not in the Active or
Stop status.
Not outputOutputNot outputA CAJ copy pair cannot be
dissolved because the R-JNL
EA2C
group is not in the Active or
Stop status.
Not outputOutputNot outputA CAJ copy pair cannot be
suspended because the M-JNL
EA33
group is not in the Active
status.
Not outputOutputNot outputA CAJ copy pair cannot be
suspended because the R-JNL
EA36
group is not in the Active
status.
Not outputOutputNot outputA CAJ copy pair cannot be
dissolved because the
EA3A
specified S-VOL status is
being changed at the
moment.
Not outputOutputNot outputA CAJ copy pair
resynchronization, which
EA3B
causes a copy direction
reversal, cannot be made
because the copy pair is in
the TRANS status.
Not outputOutputNot outputA suspension that reverses the
copy direction cannot be
EA3C
performed for the CAJ copy
pair because the specified
S-VOL belongs to the M-JNL
group.
Not outputOutputNot outputA CAJ copy pair cannot be
made because the charging
EA40
limit of the MCU program
product has been exceeded.
Not outputOutputNot outputA CAJ copy pair cannot be
made because the charging
EA41
limit of the RCU program
product has been exceeded.