HP XP7 Business Continuity Manager Messages (TK954-96003)

Table 66 Details of error codes EBxx (continued)
Type of errorError detailsError
code
OthersTHPzPATHCMDCAJCAACABC
Not outputOutputNot outputA CAJ copy pair cannot be
made because the specified
P-VOL is a command device.
EB62
Not outputOutputNot outputA CAJ copy pair cannot be
made because another
EB63
journal group pair has been
already made in the R-JNL
group.
Not outputOutputNot outputA CAJ copy pair cannot be
made because the charging
EB64
limit of the program product
has been exceeded.
Not outputOutputNot outputA CAJ copy pair cannot be
created because the specified
EB6B
S-VOL satisfies one of the
following conditions:
The S-VOL is being used
for FlashCopy.
The S-VOL is being used
for FlashCopy SE.
The S-VOL is a TSE-VOL.
Not outputOutputNot outputA CAJ copy pair cannot be
made because the CAJ
EB6E
program product is not
installed on the primary
storage system.
Not outputOutputNot outputA CAJ copy pair cannot be
resynchronized because the
EB6F
micro version on the primary
storage system does not
support the 4x4 configuration.
Not outputOutputNot outputA CAJ copy pair cannot be
made because the S-VOL had
EB70
already been paired by
another program product.
Not outputOutputNot outputA CAJ copy pair cannot be
made because the S-VOL is a
system residence volume.
EB73
Not outputOutputNot outputA CAJ copy pair cannot be
made because all of the
EB74
channel adapters connected
to the mainframe are blocked.
Not outputOutputNot outputA CAJ copy pair cannot be
made because the S-VOL is a
command device.
EB78
Not outputOutputNot outputA CAJ copy pair cannot be
made or resynchronized
because the S-VOL is online.
EB79
Not outputOutputNot outputA CAJ copy pair cannot be
made because a journal
EB7A
cache remains in the R-JNL
group.
252 Storage system sense byte information