HP XP7 Business Copy for Mainframe Systems User Guide (TK913-96001)

Run the one of the following commands to the P-VOL:
(For PPRC) CSUSPEND
For more information about the parameters and examples for using this command to split
pairs, see “CSUSPEND parameters and examples” (page 95).
(For PPRCOPY) PPRCOPY SUSPEND
For more information about the parameters and examples for using this command to split
pairs, see “PPRCOPY SUSPEND parameters and examples” (page 95).
CSUSPEND parameters and examples
The following table describes the CSUSPEND PPRC command parameters used to split pairs.
DescriptionValueParameter
NADevice numberDEVN
MPS00 is used for a steady split request.Primary volume: SSID, serial number, channel
connection address, and CU number.
PRIM
Use MAnn0 to Quick Split all pairs in a CG.
You can set MPS00 or MAnn0 instead of a
serial number.
If you set parameters other than the serial number,
MPS00 or MAnn0, the command is rejected.
Note: nn is a CTG ID.
NASecondary volume: SSID, serial number,
channel connection address, and CU number.
SEC
Not used by BC Z.Not ApplicablePRIMARY
* If you are copying the pair (“PENDING” status), Quick Split can end abnormally (reporting CC = 12). If this occurs,
wait until the copy operation ends. For more information about the prerequisites for Quick Split, see “Pair splitting
methods” (page 49).
The following image shows an example of running the CSUSPEND PPRC command:
PPRCOPY SUSPEND parameters and examples
The following table describes the PPRCOPY SUSPEND PPRCOPY command parameters used to
split pairs.
The following image shows an example of running the PPRCOPY SUSPEND PPRCOPY command:
DescriptionValueParameters
Only one of the three parameters should be
specified. The italic term is the arbitrary name.
DDNAME = dname = JCL statement identifying
the volume.
DDNAME,
SYSNAME, or
UNITADDRESS For example, dname is the arbitrary unique
SYSNAME = sysxxx = SYSNAME in the ASSGN
system control statement.
name of the JCL statement which identifies the
volume.
UNITADDRESS = ccuu = device number.
MPS00 is used for a steady split request.Primary volume: SSID, serial number, channel
connection address.
PRI
Use MAnn0 to Quick Split pairs in a CG.*
You can specify MPS00 or MAnn0 instead of a
serial number.
If you set parameters other than the serial
number, MPS00 or MAnn0, the command is
rejected.Note: nn is a CTG ID.
NASecondary volume: SSID, serial number, channel
connection address.
SEC
Splitting pairs with CSUSPEND and PPRCOPY SUSPEND 95