HP XP7 Business Copy User Guide (TK913-96002)

S-VOL accessDescriptionRWC status
Read/write enabled
S-VOL can be
mounted.
The pair has been split. The XP7 storage system stops performing update copy
operations but accepts write I/Os for the S-VOL. The XP7 storage system keeps
track of updates to split P-VOLs and S-VOL so that you can Quick Resync.
PSUS
Read onlyThe pairresync RAID Manager command is in progress. The XP7 storage
system does not accept write I/Os for S-VOL. Resynchronizing split pairs copies
only the differential data to the S-VOL.
COPY(RS)/COPY
Read onlyThe reverse pairresync RAID Manager command is in progress. The XP7
storage system copies only the S-VOL differential data to the P-VOL. The XP7
COPY(RS-R)/RCPY
storage system does not perform update copy operations during a Reverse Copy
or a Quick Restore. The XP7 storage system does not accept write I/O operations
to S-VOL.
Read onlyThe XP7 storage system does the following:PSUE
Suspends the pair.
Continues accepting read and write I/Os to the P-VOL.
Stops update copy operations to the S-VOL.
Marks the P-VOL as differential data. Resynchronizing a pair copies the P-VOL
to the S-VOL.
* The starting time of the copy depends on the numbers of pairs and the XP7 storage system environment.
Related topics
“RAID Manager pair status names” (page 64).
RAID Manager pair status names
RAID Manager pair status names can match the RWC pair status names.
The following table shows a list of the RWC pair status names and the corresponding pair status
name in RAID Manager.
RAID Manager pair status nameRWC pair status name
COPYCOPY(PD)/COPY
PAIRPAIR
COPYCOPY(SP)/COPY
PSUSPSUS(SP)/PSUS
(P-VOL) PSUSPSUS
(S-VOL) SSUS
COPYCOPY(RS)/COPY
RCPYCOPY(RS-R)/RCPY
PSUEPSUE
64 Monitoring and maintaining Business Copy