HP XP7 RAID Manager Reference Guide (T1610-96064)
Examples
For the RCU for which the product number: 64034, the RAID type: R700 and the path ID: 1 are
set, setting the options: the minimum number of paths <mpth>4, RIO MIH time<rto>15 seconds,
and round trip time 20 milliseconds are set.
# raidcom modify rcu -cu_free 64034 R700 1 -rcu_option 4 15 20
raidcom add rcu_path
Adds logical paths to RCUs.
This command is executed asynchronously with the command input. Check the completion of this
process on the raidcom get command_status command.
Syntax
raidcom add rcu_path {-rcu <serial#> <mcu#> <rcu#> -ssid <ssid>
| -cu_free <serial#> <id> <pid>} -mcu_port <port#>
-rcu_port <port#>
Options and parameters
DescriptionOption
Specifies the CU specified by serial number, <mcu#>, and <rcu#>. For XP7 Storage,
specify the number of which 300,000 is added to the serial number for <serial#>.
-rcu <serial#> <mcu#> <rcu#>
You can use hexadecimal numbers (add 0x prefix ) or decimal numbers for the <mcu#>
and <rcu#>.
Specifies the subsystem ID.-ssid <ssid>
You can use hexadecimal numbers (add 0x prefix) or decimal numbers for the <ssid>.
This parameter is used to specify CU free specified by Serial#, id#, pid#. For XP7
Storage, specify the number of which 300,000 is added to the serial number for
<serial#>.
-cu_free <serial#><id><pid>
< id > specifies the storage system type as follows:
• For XP7 use R800.
• For P9500 use R700.
• For XP24000/XP20000 Disk Array use R600.
• For XP12000 Disk Array/XP10000 Disk Array use R500.
< pid> specifies the path group ID (1-255).
Note:
The RCU is displayed by default on the GUI of Continuous Access Synchronous,
Continuous Access Journal, or Continuous Access Journal Z when "0" is specified for
<pid>.
Specifies the port number on the MCU.-mcu_port <port#>
Specifies the port number on the RCU (storage system port on the remote side).-rcu_port <port#>
Specify the port that the attribute is MCU initiator port (MCU) or RCU target port (RCU).
Examples
To the RCU for which the product number: 64034, the RAID type: R700 and the path ID: 1 are
set, adding RCU path: mcu port: CL1-A, rcu port CL1-B.
# raidcom add rcu_path -cu_free 64034 R700 1 -mcu_port CL1-A
-rcu_port CL1-B
raidcom delete rcu_path
Deletes logical paths from a specified RCU.
raidcom add rcu_path 199