HP XP7 RAID Manager Reference Guide (T1610-96064)

70 1
AOU AOU_002 CL2-D 2 10 62500 170 110000 1100000 10
70 1
Output of the raidvchkdsp command with the -v aou option:
Used(MB): Displays the usage size of the allocated block on this LUN. Range: 0 Used (MB) <
LU_CAP(MB) + 42 MB
LU_CAP(MB): Displays the LUN capacity responded to the 'Readcapacity' command as SCSI
interface.
LU_CAP(BLK): Displays the LUN capacity (in block/512 bytes) responded to the 'Readcapacity'
command as SCSI interface.
U(%): Displays the usage rate of the allocated block on the Thin Provisioning pool containing this
LU.
T(%): Displays the threshold value for WARNING set for this Thin Provisioning pool.
PID: Displays the Thin Provisioning pool ID assigned to this Thin Provisioning volume.
raidvchkscan
The raidvchkscan command displays the fibre port of the storage system (XP1024/XP128 Disk
Array and later), target ID, LDEV mapped for LUN# and MU#, and status of LDEV, regardless of
the configuration definition file.
Note:
This command is rejected with EX_ERPERM by connectivity checking between RAID Manager
and the RAID storage system.
Syntax
raidvchkscan { -h | -q | -z | -I[H][M][instance#] or
I[TC][SI][instance#] | -p <port> [hgrp] | -pd[g] <raw_device>
| -s <seq#> | -t <target> | -l <lun> | [ -f[x] ] | -v <op> }
Options and parameters
DescriptionOption
Displays Help/Usage and version information.-h
Terminates the interactive mode and exits the command.-q
Makes the raidvchkscan command enter the interactive mode. The -zx option guards performing
of the HORCM in the interactive mode. When this option detects a HORCM shut down, interactive
mode terminates.
-z or -zx
OpenVMS cannot use the -zx option.
Specifies the command as [HORC]/[HOMRCF] or [Continuous Access Synchronous]/[Business
Copy], and used when specifying the RAID Manager instance number.
-I[H][M] [instance#]
or
-I[TC][SI] [instance#]
Specifies the port ID of the port to be scanned. Valid ports are CL1-A to CL1-R and CL2-A to
CL2-R (excluding CL1-I, CL1-O, CL2-I, CL2-O). In addition, it will be able to specify from CL3-a
to CL3-r (except CL3-i, CL3-o), or CL4-a to CL4-r (except CL4-i, CL4-o) for the expanded port.
-p <port> [hgrp]
The port is not case sensitive (for example, CL1-A= cl1-a= CL1-a= cl1-A, CL3-a= CL3-A= cl3-a=
cl3-A). This option must be specified if '-find' or '-pd <raw_device>'option is not specified.
Specify [hgrp] to display only the LDEVs mapped to a host group on a port.
Specifies the raw device name. This option finds Seq# and port_name of the storage system to
which the specified device can be connected, and scans the port of the storage system which
-pd[g]
<raw_device>
corresponds with the unit ID that searches the unit ID from Seq#. This option must be specified if
the '-find' option is not specified. If this option is specified, the following -s <Seq#> option is
invalid.
86 Data management commands