HP XP7 Remote Web Console Messages (H6F56-96010)

Table 56 Error codes (part code 06005) (continued)
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
systems is in one of the following
statuses:
Maximum 4 remote storage systems
are already registered in one CU.
Maximum 64 remote storage systems
are already registered while System
is selected.
WVerify the path connections between the local
storage system and the remote storage system,
and then retry the operation.
The remote path creation was
incomplete.
00872106005
WVerify the path connections between the local
storage system and the remote storage system,
and then retry the operation.
The remote path could not be created.00872206005
WCreate a different remote path or delete all
Remote Copy pairs on the remote storage system,
and then retry the operation.
The operation was rejected because the
specified remote path is the last path of
the Remote Copy pairs.
00872306005
WIncrease the number of remote paths or specify
the minimum number of paths smaller.
The specified number of remote paths is
less than the minimum number of paths.
00872406005
WVerify the version of the microcode. If the
microcode supports Continuous Access
Current microcode version does not
support the specified operation.
00872506005
Synchronous or Continuous Access Synchronous
Z, contact HP Technical Support.
WAdd normal remote paths, and then set the
minimum number of paths, or reduce the minimum
number of paths, and then delete the remote path.
The number of normal remote paths is
less than the minimum number of paths.
00872706005
WPlease take either of the following actions: Add
normal paths, then delete the paths. Decrease the
number of minimum paths, then delete the paths.
The number of normal remote paths is
less than the minimum number of paths.
00872806005
EIf this problem persists, please contact HP
Technical Support.
An internal error occurred.00872906005
WRemove the remote connection, specify the same
logical address, and then register a remote
connection again.
The existing logical addresses are not
equal.
00873106005
WVerify the value of SSIDs of the remote storage
system. If incorrect SSIDs are registered, delete
them, and then retry the operation.
Too many SSIDs(Only Four SSIDs are
allowed).
00873206005
EInstall the required program product.The remote replication function is not
installed on the local storage system.
00873306005
EInstall the required program product.The remote replication function is not
installed on the remote storage system.
00873406005
WCheck the serial number, SSID and link address
of the RCU, and set the correct value. Then retry
The serial number, SSID, or model of the
remote storage system is invalid.
00873506005
the operation. If the same error occurs, please
contact HP Technical Support.
WDelete all Remote Copy pairs of the specified
remote storage system or SSID, and retry the
operation.
The specified remote storage system or
SSID of the remote storage system
contains some Remote Copy pairs.
00873606005
EIf this problem persists, please contact HP
Technical Support.
An internal error occurred.00873706005
150 Message (part code group 06nnn)