Table 58 Error codes (part code 06505) (continued)
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
WVerify the status of the volume specified as the
primary volume.
The Create Pairs operation cannot be
performed because the volume specified
as the primary volume is a pool volume.
05848706505
EA communication error between the local and
remote storage systems occurred, or the
The pair option was updated for the
primary volume but not updated for the
secondary volume.
05849006505
microcode of the remote storage system does not
support the change pair option function. Take a
note of the DKCMAIN microcode of the remote
storage system, and then contact HP Technical
Support to verify that the microcode supports the
change pair option function. If the microcode
supports the function, a communication error
might have occurred. Contact HP Technical
Support to solve the problem.
WVerify the DKCMAIN microcode version of the
remote storage system, and then contact HP
The Add Pair (Paircreate) operation
failed because the Continuous Access
05850006505
Technical Support to verify whether theJournal or the Continuous Access Journal
Continuous Access Journal or the ContinuousZ function of the remote storage system
does not support external volumes. Access Journal Z function supports external
volumes.
WTake a note of the DKCMAIN microcode version
of the remote storage system, and then contact
The Create Pairs operation failed
because the Continuous Access Journal
05850106505
HP Technical Support to verify whether thefunction of the Remote Storage System
does not support VMA of Data Retention. Continuous Access Journal function supports VMA
of Data Retention.
WVerify the licensed capacity of Open Array
Management for the remote storage system. To
The operation cannot be performed
because the volume capacity of the
05850206505
perform the specified operation, purchase aremote storage system exceeds the
license key that allows you to use a capacity
larger than the current capacity.
licensed capacity of Open Array
Management.
WCheck the attribute and the mirror status of the
journal.
The specified operation failed due to the
attribute or the mirror status in the
journal.
05850306505
WRefresh the window, and then retry the operation.
If this problem persists, contact HP Technical
Support.
The operation cannot be performed.05850406505
WDisable the IO suppression mode of the volume
specified as the primary volume from the External
Storage window.
The Create Pairs operation cannot be
performed because the IO suppression
mode of the volume specified as the
primary volume is enabled.
05850806505
WVerify the mirror ID assigned to the specified
primary volume from the remote storage system,
The Create Pairs operation cannot be
performed. The combination of the
05851006505
assign a mirror ID that is not used, and then retry
the operation.
specified primary volume and the mirror
ID is the same as the combination
specified from a different local storage
system.
WVerify the capacity of the volume, and specify a
volume with larger capacity.
The capacity of the specified volume is
too small.
05853006505
WCheck the emulation types of the specified
volumes.
A journal volume cannot be added
because the combination of the
05853106505
emulation types for the journal volumes
is not correct.
Part code 06505 185