HP XP7 Remote Web Console Messages (H6F56-96010)

Table 58 Error codes (part code 06505) (continued)
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
WCheck the attribute of the journal of the remote
storage system.
The specified operation failed, because
the attribute of the journal of the remote
storage system was not "restore".
05868606505
WIf this problem persists, contact HP Technical
Support.
The status of the other mirror of the Delta
resync did not change.
05868706505
WVerify the status of the specified primary volume.The delta resync operation cannot be
performed because the specified primary
volume is not ready for delta resync.
05868806505
WVerify the status of the mirrors in the specified
journal.
The operation cannot be performed
because the status of some mirrors in the
master or restore journal is invalid.
05868906505
WVerify the status of the specified primary volume.The recovery to the status ready for delta
resync cannot be made because the
05869006505
specified primary volume is in one of the
following conditions:
The volume is in data copy process
(correction copy or drive copy).
The volume is in correction access
status.
The volume is blocked.
The volume is being maintained.
The access attribute of the volume is
Read Only.
WSpecify a different mirror ID, or verify the pair
operation for the specified mirror ID.
The pair operation cannot be performed
due to one of the following reasons:
05869106505
The Create Pairs or Resync Pairs
operation (for delta resync pairs) is
performed while specifying the mirror
ID used by pairs other than delta
resync pairs.
The Create Pairs or Resync Pairs
operation (not for delta resync pairs)
is performed while specifying the
mirror ID used by delta resync pairs.
WCheck the status of the specified master journal.The specified master journal cannot be
used for Delta resync, because it is
05869206505
registered in the extended consistency
group (EXCTG).
WCheck the status of the specified restore journal.The specified restore journal cannot be
used for Delta resync, because it is
05869306505
registered in the extended consistency
group (EXCTG).
WVerify the status of the secondary volume or the
connected communication line. If no abnormality
The delta resync operation cannot be
performed.
05869406505
is found in the status, contact HP Technical
Support.
WDelete the journal registered in the extended
consistency group (EXCTG), and then retry the
operation with a different command device.
No more journals can be allocated to
the specified command device.
05869506505
WCheck the I/O suppression mode of the specified
volume.
The specified volume cannot be used as
a journal volume because the volume is
05869606505
190 Message (part code group 06nnn)