HP XP7 Remote Web Console Messages (H6F56-96010)
Table 31 Error codes (part code 01005) (continued)
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
WCorrect the settings, then retry.The specified host ID is already
registered.
00117401005
WCorrect the settings, then retry.The specified host is already registered.00117701005
WCorrect the settings, then retry.An incorrect host name was specified.00117801005
WIf this problem persists please contact HP
Technical Support.
An error occurred during SVP
processing.
00118001005
ECorrect the specification, then retry the operation.The specified path cannot be added,
because the volume is used by a Remote
Copy pair.
00118101005
WCorrect the settings, then retry.No information can be changed about
this external port because the port has
an external volume.
00119401005
WCheck the setting.The path cannot be set to the specified
volume because the volume is not an
open-systems volume.
00119901005
WTo add a path, change the attribute of the
specified port to Target or RCU Target.
Error happened before the change was
processed.
00135001005
You could not add the path to the
initiator or external port.
WSince the port you are trying to set is for Remote
Copy, you must delete the logical path, then retry
the port setting.
Logical paths remain on the Fibre-MCU
port. This operation may cause a fatal
damage to the logical paths. Please stop
00135201005
this operation. If you want to continue
this operation, please remove the logical
paths from the MCU port first.
WSince the port you are trying to set is for Remote
Copy, you must delete the S-VOL logical path that
is set to RCU Target, then retry the port setting.
S-VOLs remain on the Fibre-RCU port.
This operation may cause a fatal
damage to S-VOLs. Please stop this
00135301005
operation. If you want to continue this
operation, please remove the S-VOLs
from the RCU port first.
WTo register the WWN, change the attribute of the
specified port to Target or RCU Target.
You could not register the WWN to the
initiator or external port.
00135401005
WTo change the host mode, change the attribute of
the specified port to Target or RCU Target.
You could not change the host mode of
the host group that you connected to the
initiator or external port.
00135501005
WTo add the host group, change the attribute of the
specified port to Target or RCU Target.
You could not add the host group to the
initiator or external port.
00135601005
WThe specified port is for Fibre Continuous Access
Synchronous. Delete a logical path, then retry the
operation.
Since the logic path remains in the RCU
Target port, it cannot change.
00135701005
WReduce the number of user LU settings, then retry
the operation.
The number of User LU settings exceeds
the maximum.
00136101005
WAn error occurred during processing. If this
problem persists, please contact HP Technical
Support.
Error happened before the change was
processed.
You cannot add paths to journal
volumes.
00136301005
WCheck the port type, then retry the operation.Error happened after some change
occurred.
00136401005