Table 31 Error codes (part code 01005) (continued)
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
Please refresh the array configuration.
The port type is incorrect.
WCheck the settings, then retry.The host mode "4C" is used for a host
group connecting to volumes that cannot
be used for HP XP External Storage.
00136701005
WCheck the settings, then retry.Error happened before the change was
processed.
00136801005
The host mode "4C" can only be used
with HP XP External Storage volumes.
WVerify the host mode option or the attribute of the
port.
The specified host mode option cannot
be set to the initiator port.
00136901005
WInstall the necessary P.P. license key.Error happened before the change was
processed. This functionality is not
00160001005
available. Open System Array
Management is required.
WInstall the necessary P.P. license key.Error happened before the change was
processed. This functionality is not
00160101005
available. Open System Array
Management is required.
WPlease select another volume.Error happened before the change was
processed.The specified volume cannot
00190401005
be assigned as a command device, and
the path of the volume cannot be set
because it is being used as a Pool
volume.
WSelect another volume.Error happened before the change was
processed.The specified volume cannot
00190601005
be set as a command device because it
is being used as a V-VOL for Fast Snap.
WAn error occurred during processing. If this
problem persists, please contact HP Technical
Support.
The specified volume is a remote
command device, and therefore the
command device setting or the command
00191201005
device security setting cannot be set or
released.
WDelete the external volume that is mapped to the
external port to be operated, then retry the
operation.
An external volume is mapped to the
external port to be operated.
00191801005
WCheck the setting.Error happened before the change was
processed. The path cannot be set to the
00192601005
specified volume, because the volume
is being used as a quorum disk.
WCheck the setting.Error happened before the change was
processed. The specified volume cannot
00192701005
be set as a command device, because
it is being used as a quorum disk.
WSet Host Mode Option 60 to OFF, and then
execute addition or deletion of paths for LUN0.
Addition or deletion of paths for LUN0
cannot be done because Host Mode
00192801005
Option 60 is set to ON. Also, setting
change of Host Mode Option 60 and
path change (addition or deletion) for
LUN0 cannot be done at the same time.
Part code 01005 65