HP XP P9000 Audit Log User and Reference Guide

Table Of Contents
Detailed information
DescriptionItem
The mounting location of the PCB (Channel Adapter (CHA), Disk Adapter (DKA), or MPB) to
be restored.
PCB
The number of PCBs to be restored.Num. of PCBs
The location of the PDEV to be restored.PDEV
The parity group number.
E1-1: In case of an external volume. V1-1: In case of a virtual volume. X1-1: In case of a Thin
Provisioning volume.
PG
The number of parity groups.Num. of PGs
The LDKC number, the CU number, and the LDEV number.LDEV
The number of LDEVs.Num. of LDEVs
[Maintenance] Restore Data
Example
07xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,SVP,uid=user-name,1,,
[Maintenance],Restore Data,,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+PDEV=HDD000-00
Detailed information
DescriptionItem
The mounting location of the PDEV.PDEV
[Maintenance] Set Battery Life
This log information is output when Battery Life Warning SIM is set at the time of replacing a CM
or a battery.
Example
07xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,SVP,uid=user-name,1,,
[Maintenance],Set Battery Life,,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+{Battery,Date,Remained Life}=[{BATTERY-1CA,YYYY/MM/DD,990}],
Num. of Batteries=1
Detailed Information
DescriptionItem
The mounting location of the batteryBattery
Indicates the date of the setting in "YYYY/MM/DD" format (YYYY: year, MM: month, DD:
day)
Date
The remaining date of the battery shelf lifeRemained Life
The number of batteriesNum of Batteries
Maintenance descriptions 117