HP XP P9000 Audit Log User and Reference Guide

Table Of Contents
Basic information
DescriptionParameter
The monitored CU is enabled.Enable
Detailed information
DescriptionItem
The ID of the monitored CULDKC:CU
The logical DKC number and the CU number are separated by colons and arranged in this
order.
[Perf Mon] Edit Monitoring SW
Example
07xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,RMI AP,uid=user-name,1,
Task Name,[Perf Mon],Edit Monitoring SW,Enable 60sec,
Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
Basic information
DescriptionParameter
Monitoring is enabled and the gathering interval is set as XX sec.Enable XXsec
Monitoring is disabled.Disable
[Perf Mon] Edit WWN
Example
07xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,RMI AP,uid=user-name,1,
Task Name,[Perf Mon],Edit WWN,,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+{Update Mode,HBA WWN,Change WWN Name,Change HBA WWN}
=[{Change HBA WWN,0xXXXXXXXXXXXXXXXX,,0xXXXXXXXXXXXXXXXX},
{Change WWN Name,0xXXXXXXXXXXXXXXXX,
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX,
}],Num. of WWNs=2
Detailed information
DescriptionItem
The changing mode of WWN.Update Mode
Change HBA WWN: Change of HBA WWN, Change WWN Name: Change of WWN name.
The name of HBA WWN.HBA WWN
The new WWN name (if changed).Change WWN
Name
The name of changed HBA WWN.Change HBA WWN
The number of changed WWNs.Num. of WWNs
122 Audit log examples