HP XP P9000 Audit Log User and Reference Guide

Table Of Contents
[PROV] Edit Command Devices
Example
07xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,RMI AP,uid=user-name,1,
Task Name,[PROV],Edit Command Devices,,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+{LDKC:CU:LDEV,CommandDev}=[{0xXX:0xXX:0xXX,Disable},
{0xXX:0xXX:0xXX,Enable}],Num. of LDEVs=2
Detailed information
DescriptionItem
The LDKC, CU, and LDEV numbers of the logical volume where the command device setting is
changed.
LDKC:CU:LDEV
Indicates whether the command device setting is enabled or disabled.CommandDev
Disable or Enable will appear.
The number of logical volumes where the command device setting is changed.Num. of LDEVs
[PROV] Edit DRU Attribute
Example
07xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,RMI AP,uid=user-name,1,,
[PROV],Edit DRU Attribute,,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+{LDKC:CU:LDEV,Attribute,RT,Result}
=[{0x00:0x00:0x01,0x80,100,Normal end},
{0x00:0x00:0x02,0x82,Unlimited,Error(9605-8122)},
{0x00:0x00:0x03,0x81,200,Normal end},
{0x00:0x00:0x03,0x81,xxxx,Normal end}],
Num. of LDEVs=XXX
Detailed information
DescriptionItem
The LDKC, CU, and LDEV numbers of the logical volume where the attribute is set.LDKC:CU:LDEV
The set attribute in hexadecimal. Each bit (0–7) of 1 byte corresponds to the setting item. 1 is
assigned to each bit when the setting is enabled and 0 (zero) is assigned to each bit when
the setting is disabled. Each bit represents the following attributes:
Attribute
Bit 0: Mounting of LEDV (fixed to 1)
Bit 1: Setting of S-VOL Disable
Bit 2: Setting of Zero Read Cap mode
Bit 3: Setting of Invisible mode
Bit 4: Setting of reserve
Bit 5: Fixed to 0 (zero)
*
Bit 6: Setting of Read Only attribute
*
Bit 7: Setting of Protect attribute
*
When 0x88 is output to the attribute, for example, Read/Write attribute is set to the logical
volume to show that the reserve setting has been enabled.
A hyphen (-) is output when a setting is not changed.
The number of days set in Retention Term.RT
A hyphen (-) is output when a setting is not changed.
140 Audit log examples