HP XP P9000 Audit Log User and Reference Guide

Table Of Contents
DescriptionItem
The type of rate for the threshold or the upper limitMode
IOPS: the I/O rate
KB/s: the transfer rate
This information is output only when a threshold or an upper limit is specified.
The number of ports whose settings are changedNum. of Ports
[Perf Ctl] Set Prio WWN
Example
07xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,RMI AP,uid=user-name,1,,
[Perf Ctl],Set Prio WWN,,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+{WWN,Priority,Upper Limit,Mode}
=[{0xXXXXXXXXXXXXXXXX,Non-Prio,XXXXXXXX,IOPS}],Num. of WWNs=1
Detailed Information
DescriptionItem
A WWN of an HBAWWN
A WWN is a 16-digit number in the hexadecimal format.
An attribute specified to the HBAPriority
Prio: a prioritized WWN
Non-Prio: a non-prioritized WWN
When the WWN is a non-prioritized WWN, this information indicates the upper limit.Upper Limit
When the WWN is a prioritized WWN, this information is not output.
The type of rate for the upper limitMode
IOPS: the I/O rate
KB/s: the transfer rate
This information is not output when the WWN is a prioritized WWN.
The number of WWNs of HBAs whose settings are changedNum. of WWNs
NOTE:
When the attribute of the host bus adapter in the PFC group changes from a prioritized WWN
to a non-prioritized WWN, "Non-Prio" is output to Priority and "0" is output to Upper limit
respectively.
If multiple changes in settings such as Priority and Upper limit are made in succession and
then Apply is clicked at the end of the operation, these set values are output one by one in
the order they were configured.
[Perf Ctl] PFCGrp Del/Chg
Example
07xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,RMI AP,uid=user-name,1,,
[Perf Ctl],PFCGrp Del/Chg,,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+{Mode,PFC Group,Change Name}
Performance Control Descriptions 187