HP XP P9000 Audit Log User and Reference Guide

Table Of Contents
DescriptionItem
Yes: support, No: not support
The SCP delay time when the pair is suspended. The unit is second.SCP Time(s)
The number of parallel operation of initial copy by CU. (1 to 16).Max Initial Copy
The number of CUs set.Num. of CUs
[Cnt Ac-S] Change Pair Option
Example
07xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,RMI AP,uid=user-name,1,,
[Cnt Ac-S],Change Pair Option,,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+{P-VOL(Port-G-ID-LUN),Fence Level,Result}
=[{1A-0x00-0x000,Never,Normal end},
{1A-0x00-0x001,Never,Normal end},
{1A-0x00-0x002,Never,Normal end},(snip)
-(snip)],Num. of Pairs=xx
Detailed information
DescriptionItem
The port number, host group number and LUN of the primary volume where the pair option is
changed sequentially.
P-VOL(Port-G-ID-LUN)
The changed fence level (the condition that MCU rejects Write to the primary volume).Fence Level
Never: No condition, Data: S-VOL data, Status: S-VOL status
The result of operation.Result
Normal end: Normal end, Error (xxxx-yyyyy): Abnormal end
xxxx: Part code, yyyyy: Error code
The number of changed pairs.Num. of Pairs
[Cnt Ac-S] Function Switch
Example
07xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,RMI AP,uid=user-name,1,,
[Cnt Ac-S],Function Switch,,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+ Switch=0001 0100 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000
Detailed information
DescriptionItem
Each bit position (on/off) of the function switch information assigned by 64 bits. The
beginning of the string is bit 0 and the ending of it is bit 63. "0" indicates the bit is off,
and "1" indicates the bit is on.
Switch
In the example above, bit 3 and bit 5 are on and the other bits are off.
[Cnt Ac-S] Paircreate
Example
07xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,RMI AP,uid=user-name,1,,
[Cnt Ac-S],Paircreate,,Normal end,
192 Audit log examples