HP XP P9000 Audit Log User and Reference Guide

Table Of Contents
Detailed information
DescriptionItem
The LDKC number of the journal.LDKC
The journal number.JNL
The overflow watch time of the metadata or journal data (in seconds).Data Overflow
Watch(s)
Indicates whether inflow control is executed or not.Inflow Control
Yes: Controlled, No: Not controlled
Whether to store the journal data in the restore journal in cache.Use of Cache
Use: Store the journal data in cache. Not Use: Store the journal data in journal volume
The result of the operation.Result
Normal end: Normal end, Error (xxxx-yyyyy): Abnormal end
xxxx: Part code, yyyyy: Error code
The number of journals.Num. of JNLs
[Cnt Ac-J] Change-Mirror-Option
Example
07xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,RMI AP,uid=user-name,1,,
[Cnt Ac-J],Change-Mirror-Option,,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+{LDKC,JNL,MirrorID,Copy Pace,Path Watch Time,
Forward Path Watch Time,Transfer Speed(Mbps),
Delta resync Failure,Result}
=[{0x00,0x001,0x00,Medium,12(hour),Yes,100,Entire,Normal end},
{0x00,0x002,0x00,Low,1(day),No,
10,None,Normal end}],Num. of Mirrors=2
Detailed information
DescriptionItem
The LDKC number of the journal.LDKC
The journal number.JNL
The mirror ID.MirrorID
The speed of initial copy.Copy Pace
Low: Low speed, Medium: Medium speed, High: High speed
The path watch time period setting. The units are minutes, hours or days. If it is set to 30
minutes, it will be 30(min.).
Path Watch Time
Indicates whether to transfer the forward path watch time period of the master journal to the
restore journal.
Forward Path Watch
Time
Yes: Transfer, No: Do Not Transfer.
The transfer speed of the communication line. The unit is megabits per second (Mbps).Transfer Speed(Mbps)
Indicates the operation mode when Delta resync operation have failed.Delta resync Failure
Entire: Copy the entire data volume, None: Do not copy the data volume
The result of operation.Result
Continuous Access Journal descriptions 201