HP XP P9000 Audit Log User and Reference Guide

Table Of Contents
Example 2: Set the cache inflow control
07xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,RMI AP,uid=user-name,1,
Task Name,[Ext Stor],Edit ES VOLs, InflowControl,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+{Group,Mode,Result}=[{E1-1,Enable,Normal end},
{E1-2,Enable,Normal end},{E1-3, Enable,Normal end},
{E1-4, Enable,Normal end}],Num. of Groups=4
Basic information
DescriptionParameter
The cache mode is changed.Cachemode
The cache inflow control is set.InflowControl
Detailed information
DescriptionItem
External volume group number for the executed setting operation.Group
Whether the setting is enabled or disabled.Mode
Enable: Enabled, Disable: Disabled
The result of operation.Result
Normal end: Normal end, Error (xxxx-yyyyy): Abnormal end
xxxx: Part code, yyyyy: Error code
The number of external volumes groups configured.Num. of Groups
Example 3: Changing a load balance mode
07xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,RMI AP,uid=user-name,1,
Task Name,[Ext Stor],Edit ES VOLs,LoadBalanceMode,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+{Group,Mode,Result}=[{E1-1,Normal Round-robin,Normal end},
{E1-2,Normal Round-robin,Normal end}],Num. of Groups=2
Basic Information for Example 3
DescriptionParameter
The load balance mode is changed.LoadBalanceMode
Detailed Information for Example 3
DescriptionItem
External volume group number for the executed setting operationGroup
The load balance mode after the changeMode
Normal Round-robin, Extended Round-robin, or Disable will appear.
The result of operationResult
Normal end: Normal end,
Error(xxxx-yyyyy): Abnormal end
where xxxx: Part code, yyyyy: Error code
The number of external volumes groups configuredNum. of Groups
222 Audit log examples