DescriptionItem
ON: Report, OFF: Do not report
Report serious level information as a SIM.Serious
ON: Report, OFF: Do not report
Report moderate level information as a SIM.Moderate
ON: Report, OFF: Do not report
Report service level information as a SIM.Service
ON: Report, OFF: Do not report
The number of information levels to be reported as a SIM.Num. of Types
[Information] Threshold Value
Example 1
07xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,SVP,uid=user-name,1,,
[Information],Threshold Value,Alter,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+Type=7days
+{Mechanical error(Recovered,Unrecd.),Media error(Recovered,
Unrecd.),Read/Write error(Recovered,Unrecd.),
Drive I/F error(Recovered,Unrecd.),
Controller hardware error(Recovered,Unrecd.),
SAS I/F error Port 0(Unrecd.),
SAS I/F error Port 1(Unrecd.),Port 0 error(Unrecd.),
Port 1 error(Unrecd.)}
={(150,60),(0,15),(150,30),(150,6),(150,6),6,6,12,12}
++PDEV=[HDD000-01,HDD000-02],Num. of PDEVs=2
Example 2
07xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,SVP,uid=user-name,1,,
[Information],Threshold Value,Error Reset,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+PDEV=HDD000-01
Basic information
DescriptionParameter
Change the threshold of failed PDEV.Alter
Indicates Error Reset.Error Reset
Detailed information
DescriptionItem
The period of time to acquire the result of threshold diagnosis using the read diagnosis
function.
Type
7days: 7 days, Total: Every operating days
The threshold of the Mechanical error.Mechanical error
(Recovered,Unrecd.)
The threshold of the Media error.Media error
(Recovered,Unrecd.)
Information descriptions 73