HP XP P9000 Audit Log User and Reference Guide

Table Of Contents
[Install] Dku Emulation
Example
07xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,SVP,uid=user-name,1,,
[Install],Dku Emulation,,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+Type=3390-3A
+Type=3390-3A
++LDEV(LDKC:CU:LDEV)=[0x00:0x00:0x02,0x00:0x00:0x03],
Num. of LDEVs=2
+Type=3390-3B
++LDEV(LDKC:CU:LDEV)=[0x00:0x00:0x04,0x00:0x00:0x05],
Num. of LDEVs=2
+Num. of Emulation Types=3
Detailed information
DescriptionItem
The emulation type.Type
The LDKC, CU, and LDEV numbers where the emulation type is changed.LDEV(LDKC:CU:LDEV)
The number of logical volumes where the emulation type is changed.Num. of LDEVs
The number of emulation types.Num. of Emulation Types
[Install] FlashDrive ORM Value
Example
07xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,SVP,uid=user-name,1,,
[Install],FlashDrive ORM Value,,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+{Flash Drive Collective setting,Dynamic Sparing,Warning SIM}
={Valid,99,95}
+{FMD Battery Collective setting,Warning SIM}={Valid,95}
Detailed Information
DescriptionItem
Indicates whether the flash drive collective setting information is valid or invalidFlash Drive Collective
Setting
Valid: Valid, Invalid: Invalid
The threshold of starting Dynamic Sparing threshold of flash driveDynamic Sparing
The threshold of thewarning SIM threshold of flash driveWarning SIM
Indicates whether the FMD battery collective setting information is valid or invalidFMD Battery Collective
setting
Valid: Valid, Invalid: Invalid
The warning SIM threshold of FMD batteryWarning SIM
[Install] Force Reset
Example
07xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,SVP,uid=user-name,1,,
[Install],Force Reset,,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+{Port,HostGrpID,LUN}
Install descriptions 79