HP XP7 Audit Log User and Reference Guide (H6F56-96001)

Table Of Contents
[Install] Set Subsystem Time
Example 1: The case of TOD Change
08xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,SVP,uid=user-name,1,,
[Install],Set Subsystem Time,TOD Change,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+Time=YYYY/MM/DD HH:mm:SS
Example 2: The case of Synchro. Infor.
For IPv4
08xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,SVP,uid=user-name,1,,
[Install],Set Subsystem Time,Synchro. Infor.,Normal end,
from=xxx:xxx:xxx:xxx,,Seq.=xxxxxxxxxx
+{Use Synchro.,SNTP IP,SNTP Port,Time Zone,Check Time,
Create SIM}
={Valid,(123.456.789.123),100,Tokyo Standard Time,23,ON}
For IPv6
08xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,SVP,uid=user-name,1,,
[Install],Set Subsystem Time,Synchro. Infor.,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+{Use Synchro.,SNTP IP,SNTP Port,Time Zone,Check Time,
Create SIM}
={Valid,(1111:2222:3333:4444:5555:6666:7777:8888),100,
Tokyo Standard Time,23,ON}
Basic Information
DescriptionParameter
The date and the timeTOD Change
The setting of time correction functionSynchro. Infor.
Detailed Information
DescriptionItem
Indicates the date and the time in the format of "YYYY/MM/DD HH:mm:SS".(YYYY: year,
MM: month, DD: date, HH: hour, mm: minute, SS: second).
Time
Indicates whether the time correction function is valid or invalid.Use Synchro.
Valid: Enable, Invalid: Disable
The IP address (IPv4 or IPv6) of SNTP server.SNTP IP
The port used by SNTP server.SNTP Port
The time zone.Time Zone
The time when the time correction function is executed. Only HH (Hour: 00 to 23) is indicated
for the execution time.
Check Time
Indicates whether the SIM was created or not when the setting of time correction failed.Create SIM
ON: Created, OFF: Not created.
[Install] Set UserAuth
Example
08xx, YYYY/MM/DD,HH:MM:SS.xxx, 00:00,SVP,uid=user-name,1,,
[Install],Set UserAuth,,Normal end,
100 Audit log examples