DescriptionItem
The LDKC number, the CU number and the LDEV number of the secondary volume in the
suspended pair
S-VOL (LDKC:CU:LDEV)
The result of the operationResult
Normal end: Normal end, Error(xxxx-yyyyy): Abnormal end
xxxx: Part code, yyyyy: Error code
The number of suspended pairsNum. of Pairs
Maintenance Descriptions
[Maintenance] Blockade
Example 1: blocking a PCB
08xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,SVP,uid=user-name,1,,
[Maintenance],Blockade,,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+PCB=[CHA-1PC],Num. of PCBs=1
Example 2: blocking an LDEV
08xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,SVP,uid=user-name,1,,
[Maintenance],Blockade,,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+PG=[1-1],Num. of PGs=1
Detailed Information
DescriptionItem
The mounting location of the PCB (Channel Adapter (CHA), Disk Adapter (DKA), CM, MPB)
to be blocked
PCB
The number PCB to be blockedNum. of PCBs
The mounting location of the PDEV (physical device) to be blockedPDEV
The parity group numberPG
E1-1: In case of an external volume
V1-1:In case of a virtual volume
X1-1: In case of a Thin Provisioning volume
The number of parity groupsNum. of PGs
The LDKC number, the CU number, and the LDEV numberLDEV
The number of LDEVsNum. of LDEVs
[Maintenance] Correction Copy
Example
08xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,SVP,uid=user-name,1,,
[Maintenance],Correction Copy,,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+PDEV=HDD000-00
110 Audit log examples