HP XP7 Audit Log User and Reference Guide (H6F56-96001)

Table Of Contents
[PROV] Create LDEVs
Example 1: Creating internal volumes or external volumes
08xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,RMI AP,uid=user-name,1,
Task Name,[PROV],Create LDEVs,Basic,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+{PG,LDKC:CU:LDEV,Start LBA,Emulation,Size,Unit,MP Blade ID}
=[{XX-XX,0xXX:0xXX:0xXX,XXXXXXXX,OPEN-V,XXXXXXXX,KB,Auto},
{XX-XX,0xXX:0xXX:0xXX,XXXXXXXX,OPEN-V,XXXXXXXX,KB,0xX}],
Num. of LDEVs=2
Basic Information for Example 1
DescriptionParameter
Create LDEVs was done to basic volumesBasic
Create LDEVs was done to external volumesExternal
Create LDEVs was done to both basic volumes and external volumesBasic/External
Detailed Information for Example 1
DescriptionItem
The parity group number.PG
An E at the beginning of a parity group number designates an external volume is present
in that parity group.
The LDKC, CU, and LDEV numbersLDKC:CU:LDEV
The start LBA.Start LBA
A hyphen (-) is output when not specified.
The emulation typeEmulation
The user-specified capacitySize
The unit of the CV capacity.Unit
LBA is displayed.
This capacity value can be converted into kilobytes by dividing by two because one block
is 512 bytes.
For information about how to convert the capacity value into cylinders, see the section
describing size calculation in HP XP7 Provisioning for Mainframe Systems User Guide.
The specified MP blade ID.MP Blade ID
"Auto" indicates the processor blade number is set automatically.
The number of LDEVsNum. of LDEVs
Example 2: Creating Fast Snap volumes
08xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,RMI AP,uid=user-name,1,
Task Name,[PROV],Create LDEVs,Snapshot,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+{Pool ID,LDKC:CU:LDEV,LDEVCapa(blocks),Emulation,CLPR,SSID,
MP Blade ID,Result}=[{-,0x00:0x00:0x00,96000,OPEN-V,0,0x0004,
Auto,Normal end},{-,0x00:0x01:0x00,96000,OPEN-V,0,0x0005,,Auto,
Normal end}],Num.of LDEVs=2
Provisioning Descriptions 129