HP XP7 Audit Log User and Reference Guide (H6F56-96001)

Table Of Contents
Path Blockade Watch(s),Path Blockade SIM Watch(s),
Service SIM,Switch}
={128,Enable,45,070,Not Report,-}
+{LDKC,CU,Service SIM,PPRC Support,Max Initial Copy}
=[{0x00,0x00,Not Report,Yes,04},
{0x00,0x01,Not Report,Yes,04},
{0x00,0x02,Not Report,Yes,04},
{0x00,0x03,Not Report,Yes,04},
{0x00,0x04,Not Report,Yes,04},(Snip)-(Snip)],
Num. of CUs=255
Example 4: Editing remote replication function switch
08xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,RMI AP,uid=user-name,1,,
[Remote Replication],Edit Options,,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+Copy Type=Cnt Ac-S,{Max Initial Copy,CU Activity,
Path Blockade Watch(s),Path Blockade SIM Watch(s),
Service SIM,Switch}
={-,-,-,-,-,1000 0000 0000 0000 0100 0000 0000 0000 0000 0000
0000 0000 0000 0000 0000 0000}
Detailed Information
DescriptionItem
The program product name for this operationCopy Type
Cnt Ac-S: Continuous Access Synchronous
The maximum number of initial copy operations setMax Initial Copy
If this is not a subject to change, a hyphen (-) is displayed. If any one of Max Initial Copy,
CU Activity, Path Blockade Watch(s), Path Blockade SIM Watch(s), and Service SIM is
changed, this will be the subject to change.
Indicates whether the parallel operation of initial copy by the control unit is enabled or not.CU Activity
Enable or Disable will appear.
If this is not a subject to change, a hyphen (-) is displayed. If any one of Max Initial Copy,
CU Activity, Path Blockade Watch(s), Path Blockade SIM Watch(s), and Service SIM is
changed, this will be the subject to change.
The path blockade watch period setting (in seconds).Path Blockade Watch(s)
If this is not a subject to change, a hyphen (-) is displayed. If any one of Max Initial Copy,
CU Activity, Path Blockade Watch(s), Path Blockade SIM Watch(s), and Service SIM is
changed, this will be the subject to change.
The path blockade SIM watch period setting (in seconds).Path Blockade SIM
Watch(s)
If this is not a subject to change, a hyphen (-) is displayed. If any one of Max Initial Copy,
CU Activity, Path Blockade Watch(s), Path Blockade SIM Watch(s), and Service SIM is
changed, this will be the subject to change.
Indicates whether the remote replication related SIM is reported or not.Service SIM
Report, Not Report
If this is not a subject to change, a hyphen (-) is displayed. If any one of Max Initial Copy,
CU Activity, Path Blockade Watch(s), Path Blockade SIM Watch(s), and Service SIM is
changed, this will be the subject to change.
Each bit position (on/off) of the function switch information assigned by 64 bits. The beginning
of the string is bit 0 and the ending of it is bit 63. "0" indicates the bit is off, and "1" indicates
the bit is on. In the example above, bit 3 and bit 5 are on and the other bits are off.
Switch
If this is not a subject to change, a hyphen (-) is displayed.
The LDKC numberLDKC
182 Audit log examples