HP XP7 Audit Log User and Reference Guide (H6F56-96001)

Table Of Contents
Detailed Information
DescriptionItem
An executed operationMode
Add WWN: Added a WWN (an HBA is monitored).
Delete WWN: Deleted a WWN (an HBA is not monitored).
An added or deleted WWNWWN
A WWN is a 16-digit number in the hexadecimal format.
A PFC name for an added or deleted HBAPFC Name
An attribute specified to the HBAPriority
Prio: a prioritized WWN
Non-Prio: a non-prioritized WWN
This information is output only when a WWN (HBA) is added.
A name of the port where the HBA is addedPort
The number of ports where the HBA is addedNum. of Ports
The number of added or deleted WWNsNum. of WWNs
[Perf Ctl] Update PFCGrp
Example
08xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,RMI AP,uid=user-name,1,,
[Perf Ctl],Update PFCGrp,,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+{UpdateMode,PFC Group,Priority,Upper Limit,Mode}
=[{Add New Group,XXXXXXXXXXXXXXXX,Non-Prio,XXXXXXXX,IOPS},
++WWN=[0xXXXXXXXXXXXXXXXX,0xXXXXXXXXXXXXXXXX],Num. of WWNs=2],
+Num. of PFC Group=1
Detailed Information
DescriptionItem
An executed operationUpdate Mode
Add New Group: Added a new PFC group.
Add WWN: Added an HBA to the PFC group
Delete WWN: Deleted an HBA from the PFC group
A PFC group namePFC Group
An attribute specified to the HBAPriority
Prio: a prioritized WWN
Non-Prio: a non-prioritized WWN
This attribute is applied to all HBAs in the PFC group.
This information is output only when you add a new PFC group.
When an attribute specified to the PFC group is Non-Prio, this information indicates an upper
limit of the HBAs in the PFC group.
Upper Limit
This information is output only when you add a new PFC group.
The type of rate when you specify an upper limit.Mode
IOPS: the I/O rate
202 Audit log examples