HP XP7 Audit Log User and Reference Guide (H6F56-96001)

Table Of Contents
DescriptionItem
The topology of the Fabric switchConnection
FC-AL: FC-AL (Fibre Channel-Arbitrated Loop) is selected
P-to-P: Point-to-Point is selected
Indicates whether the LUN security setting is enabled or disabledSwitch
Enable or Disable will appear
The serial number of the virtual storage machineVirtual Storage Machine S/N
No output when a virtual storage machine is not specified
Indicates the 16 byte parameter added in the storage system and the command
parameter in binary format
Command parameter
Modify Port Attribute
Example
08xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,Out-of-band,uid=user-name,
196,,[Config Command],,,Accept,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+Command=Modify Port Attribute
++Port=1A,Attribute=Target
+0000010200000000 0000000000000000
+0123456789ABCDEF 0123456789ABCDEF 0123456789ABCDEF,(snip)
Detailed Information
DescriptionItem
The command nameCommand
The name of a port whose attribute is to be changedPort
The attribute after the changeAttribute
Target: Target attribute
Initiator: Initiator attribute
External: External attribute
RCU Target: RCU Target attribute
Indicates the 16 byte parameter added in the storage system and the command
parameter in binary format
Command parameter
Modify RCU
Example
08xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,Out-of-band,uid=user-name,
196,,[Config Command],,,Accept,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+Command=Modify RCU
++S/N=XXXXX,MCU=X,RCU=X
+0000010200000000 0000000000000000
+0123456789ABCDEF 0123456789ABCDEF 0123456789ABCDEF,(snip)
Config Command (Open system) 265