HP XP7 Audit Log User and Reference Guide (H6F56-96001)

Table Of Contents
DescriptionItem
The parity group numberPG
The RAID LevelRAID Level
The type of the driveDrive Type
The emulation typeEmulation
The RAID concatenated parity group number. A hyphen (-) is indicated when the parity group
is not RAID concatenated.
Concatenation
The status of encryptionEncryption
Enable: Enabled, Disable: Disabled
The LDKC number, the CU number, and the LDEV numberLDKC:CU:LDEV
The capacity of CVSize
The unit of the capacity of CVUnit
The storage system IDSSID
The ownership of the MPBMPB
The number of LDEVsNum. of LDEVs
The number of parity groupsNum. of PGs
The B4 numberB4
The spare drive numberSPARE
The number of spare drivesNum. of SPAREs
Example 4: installing additional cache memory
This logged information indicates until the formatting is requested (not until the formatting process
is complete). However, if the operation does not request the formatting, it indicates the logged
information after completing the volume creation.
08xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,SVP,uid=user-name,1,,
[Install],Install,,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+{CM,CMG,Size}
=[{1CA/2CA,CM16G x 2,65536},{1CB/2CB,CM16G x 2,65536},
{1CC/2CC,CM16G x 2,65536},{1CD/2CD,CM16G x 2,65536}],Num. of CMs=4
+{BKM,Type,Size}=[{1BA/2BA,BKML,BMM128 x 2(400GB)},
{1BB/2BB,BKML,BMM128 x 2(400GB)},{1BC/2BC,BKML,BMM128 x 2(400GB)},
{1BD/2BD,BKML,BMM128 x 2(400GB)}],Num. of BKMs=4
+DCR available size=2048
+{CLPR,Cache size,DCR size,Extent Number}
=[{CLPR0,217088,3072,15384},{CLPR1,8192,1024,1000}],
Num. of CLPRs=2
+PP Flag=[(64KLDEV, SI/VM Extension, TPF),(TC/UR)],
Num. of PP Flags=2
+Max Number of CUs=255
+{Battery,Date,Remained Life}=[{BATTERY-1BA,YYYY/MM/DD,990},
{BATTERY-2BC,YYYY/MM/DD,990}],Num. of Batteries=2
Detailed Information for Example 4
DescriptionItem
The mounting location of the PCB for cache memoryCM
The capacity of CMGCMG
Install Descriptions 83