HP XP7 Auto LUN User Guide (TK915-96001)

Table 20 RAID Manager errors related to migration plans (continued)
Required ActionMessageError Code
(SSB2)
Wait until the capacity increase is completed.
Then, you must specify a source volume which has
The migration target volume is a Thin Provisioning
or Smart Tiers virtual volume whose capacity is
increasing.
20A6
the same capacity as the volume whose capacity
is increased and migrate the volume.
Wait until the Thin Provisioning or Smart Tiers
virtual volume reclaims zero pages, and then
migrate the volume.
The migration source volume is a Thin Provisioning
or Smart Tiers virtual volume in which the zero
pages are being reclaimed.
20AD
Wait until the Thin Provisioning or Smart Tiers
virtual volume reclaims zero pages, and then
migrate the volume.
The migration target volume is the Thin
Provisioning or Smart Tiers virtual volume in which
the zero pages are being reclaimed.
20AE
Set an LU path to the volume and then migrate the
volume.
The volume specified as a migration source volume
has no LU path.
20BA
Set an LU path to the volume and then migrate the
volume.
The volume specified as a migration target volume
has no LU path.
20BB
The volume cannot be migrated. Check the
configuration definition file.
The emulation type of the migration source volume
is 3390-V.
20C0
The volume cannot be migrated. Check the
configuration definition file.
The emulation type of the migration target volume
is 3390-V.
20C1
Perform the operation again after the power supply
turning on.
The power supply is switched off.20C5
The volume cannot be migrated. Check the
configuration definition file.
The emulation type of the migration source volume
is 6588-A.
20C6
The volume cannot be migrated. Check the
configuration definition file.
The emulation type of the migration target volume
is 6588-A.
20C7
If Mainframe Fibre CHAs are not installed, install
them.
The emulation type of the migration source volume
is 3390-A, and one of the following applies:
20CC
If all Mainframe Fibre CHAs are being blocked,
restore them.
Mainframe Fibre CHAs are not installed.
All Mainframe Fibre CHAs are being blocked.
If Mainframe Fibre CHAs are not installed, install
them.
The emulation type of the migration target volume
is 3390-A, and one of the following applies:
20CD
If all Mainframe Fibre CHAs are being blocked,
restore them.
Mainframe Fibre CHAs are not installed.
All Mainframe Fibre CHAs are being blocked.
Perform the operation again after the initialization
of the THP pool has finished.
The migration source volume is a Thin Provisioning
or Smart Tiers virtual volume whose THP pool is
being initialized.
20D3
Perform the operation again after the initialization
of the THP pool has finished.
The migration target volume is a Thin Provisioning
or Smart Tiers virtual volume whose THP pool is
being initialized.
20D4
The volume cannot be migrated. Check the
configuration definition file.
The migration source volume is a TSE-VOL.20D9
The volume cannot be migrated. Check the
configuration definition file.
The migration target volume is a TSE-VOL.20DA
Perform the operation again after checking the
configuration definition file.
The settings for online data migration of the source
volume is incorrect.
20E1
The volume cannot be migrated. Check the
configuration definition file.
The migration target volume is an external volume
mapped for online data migration.
20E2
Troubleshooting when using RAID Manager 35