HP XP7 Continuous Access Journal for Mainframe Systems User Guide (TK911-96001)

DescriptionError code (SSB2)
The pair cannot be created because the status of the configuration could not be transited.8F53
The pair cannot be created or resynchronized because of the one of following reasons.8F58
The pair status of the specified S-VOL differed from the one of P-VOL.
The state of restore journal differed from the state of master journal.
The pair cannot be created because the specified secondary system did not support the external
volume.
8F67
The pair cannot be created because the specified volume was a command device.8F6D
The pair cannot be created because the P-VOL is used for Fast Snap.8FEA
The pair cannot be created because the P-VOL is used for Fast Snap.8FEC
The command cannot be executed because user authentication is not performed.9100
The required shared memory for operating Cnt Ac-J Z is not installedB91C
The information of the consistency group cannot be retrieved, because Continuous Access Journal
Z was not installed.
B992
The source of command devise has run out. Set to OFF the command device and to ON again
from the LUN Manager.
B9C0
RAID Manager error codes for Cnt Ac-J Z: SSB1 = B9E1
DescriptionError code (SSB2)
The command was rejected because the specified device is a command device.B901
RAID Manager error codes for Cnt Ac-J Z: SSB1 = B901, B9E0, B9E1, B9E2,
B9E4, D004
DescriptionError code (SSB2)
The command was rejected because the mirror ID is invalid.B902
The command was rejected because the volume was unpaired.B907
The S-VOL hide mode is not supported.B90A
The command was rejected because the Cnt Ac-J Z program product is not installed.B90D
The command was rejected because the mirror ID is invalid.B909
A status of Cnt Ac-J Z pair was acquired at the time of unavailable to use the Cnt Ac-J Z during
the power-on. Retry the operation.
B900
The command was rejected because the Cnt Ac-J Z configuration was changed. Check the status
of the Cnt Ac-J Z pair.
B94B
The command was rejected because the path is not set between the systems.B90E
A request for a Cnt Ac-J Z Paircreate operation was rejected because neither Cnt Ac-J Z nor Cnt
Ac-S Z was installed.
B90F
The settings of the journal option could not be updated.B910
The command was rejected because the system configuration does not allow these operations.B913
The command was rejected because no journal was registered.B912/B9F8
The pair cannot be created because the system identifier is not correct (left-most number in the
6-digit serial number).
B920
122 Cnt Ac-J Z troubleshooting