HP XP7 Continuous Access Journal for Mainframe Systems User Guide (TK911-96001)

DescriptionError code (SSB2)
The command was rejected because the state of S-VOL was not SSWS.EA25
The command was rejected because the state of master journal was other than Active or Stopped.EA29
The command was rejected because the state of restore journal was other than Active or Stopped.EA2C
The command was rejected because the state of mater journal was other than Active.EA33
The command was rejected because the state of restore journal was other than Active.EA36
The command was rejected because the specified S-VOL was in the state of status transition.EA3A
The command was rejected because the specified S-VOL was in the state of Suspending.EA3B
The command was rejected because the desired capacity exceeded the charging capacity of
the primary system's program product.
EA40
The command was rejected because the desired capacity exceeded the charging capacity of
the secondary system's program product.
EA41
The command was rejected because the paircreate or pairresync cannot run with the journal’s
attribute or mirror status.
EA89
The command was rejected because the pair status could not be changed during the power-on
or power-off processing.
EA8A
The command was rejected because the specified volume is used in the system that consists of
multiple primary and secondary systems.
EA8B
The command was rejected because the microcode was being replaced.EA92
The command was rejected because the volume specified for the P-VOL was initializing the pool
of Thin Provisioning Z.
EA95
The command was rejected because the desired capacity exceeded the charging capacity of
the primary system's Cnt Ac-J Z. Check the license capacity as well as the related program
product.
EAA2
The command was rejected because the desired capacity exceeded the charging capacity of
the secondary system's Continuous Access Synchronous Z. Check the License capacity as well
as the related Program product.
EAA3
The command was rejected because the desired capacity exceeded the charging capacity of
the secondary system's Cnt Ac-J Z. Check the license capacity as well as the related program
product.
EAA5
The command was rejected because the desired capacity exceeded the charging capacity of
the primary system's Continuous Access Synchronous Z. Check the license capacity as well as
the related program product.
EAA6
Pair creation failed because there is no available differential management area of the primary
storage system. If additional shared memory is not installed in the primary system, install it and
EAB6
then retry the operation. If additional shared memory is installed, the pair cannot be created
because the maximum number of pairs is exceeded.
The paircreate operation failed because no extended shared memory is installed in the primary
system. Install extended shared memory in the primary system and then repeat the operation.
EAB7
Pair creation failed because there is no available differential management area of the secondary
system. If additional shared memory is not installed in the secondary system, install it and then
EAB8
retry the operation. If additional shared memory is installed, the pair cannot be created because
the maximum number of pairs is exceeded.
The paircreate operation failed because no extended shared memory is installed in the secondary
system. Install extended shared memory in the secondary system and then repeat the operation.
EAB9
The pair operation failed because the shared memory is not installed in the specified LDEV number.EABC
The command was rejected because the delta resync function was unsupported.EAD0
Troubleshooting with RAID Manager 125