HP XP7 Continuous Access Journal for Mainframe Systems User Guide (TK911-96001)

DescriptionError code (SSB2)
The command was rejected because the access attribute was set to the specified P-VOL or S-VOL
by the Data Retention.
EB5B
The command was rejected because an internal logical error occurred.EB5C
The command was rejected because the S-VOL was already paired.EB5E
The command was rejected because the program product of Cnt Ac-J Z was not installed in the
secondary system.
EB5F
The command was rejected because the P-VOL capacity is not the same as the S-VOL’s.EB60
The command was rejected because the path between the primary and the secondary systems
was not valid.
EB61
The command was rejected because the specified P-VOL was a command device.EB62
The command was rejected because the restore journal was already linked with another journal.EB63
The command was rejected because the desired capacity exceeded the charging capacity of
the program product.
EB64
The command was rejected because of the abnormal end which is related to the charging capacity
of the program product.
EB65
The command was rejected and the retry processing was ordered because P-VOL SUSPENDING
was detected when the RAID Manager ReverseResync command was executed.
EB66
The Cnt Ac-J Z pair cannot be created nor resynchronized because of the one of following reasons.EB6B
The specified S-VOL is used by Compatible FlashCopy.
The specified S-VOL is TSE-VOL or being used by Compatible FlashCopy SE.
The Cnt Ac-J Z pair create processing was doubly executed:EB6C
There are no problems if the initial copy operation is restarted when the primary storage
system is powered off.
There are no problems if a Cnt Ac-J Z pair is created when the primary storage system is reset.
The command was rejected because the Cnt Ac-J Z program product was not installed in the
primary system.
EB6E
The command was rejected because the specified S-VOL is assigned to a copy pair of other
program products.
EB70
The command was rejected because the specified S-VOL is the system disk.EB73
The command was rejected because all mainframe connection CHAs are blockaded.EB74
The command was rejected because the specified data volume is a command device.EB78
The command was rejected because the specified data volume is online.EB79
The command was rejected because the journal cache of the restore journal was remained.EB7A
The command was rejected because the specified S-VOL is an external volume.EB7D
The command was rejected because the specified S-VOL is in one of the following statuses.EB7E
The specified S-VOL is being used for a Business Copy Z pair.
The specified S-VOL is a reserved volume.
The specified S-VOL is a Business Copy Z P-VOL and registered to a Business Continuity
Manager consistency group and a RAID Manager consistency group.
Cnt Ac-J Z P-VOL and S-VOL are THP V-VOL, and the specified S-VOL is being used as Business
Copy Z P-VOL.
Troubleshooting with RAID Manager 127