HP XP7 Continuous Access Journal for Mainframe Systems User Guide (TK911-96001)

DescriptionError code (SSB2)
Cnt Ac-J Z P-VOL and S-VOL are THP V-VOL, and the specified S-VOL is the source volume of
Auto LUN.
Cnt Ac-J Z P-VOL and S-VOL are THP V-VOL, and the specified S-VOL is being used as Fast
Snap P-VOL.
The command was rejected because the emulation type of the specified S-VOL was unsupported.EB7F
The command was rejected because the specified volume was the V-VOL or the pool-VOL. Please
check the status of the volume.
EB80
The command was rejected because the path from the secondary system to the primary system
is not set, or the volume used as the S-VOL is not paired.
EB87
The command was rejected because of one of the following:EB88
The specified S-VOL was being used as a Business Copy Z S-VOL.
The specified S-VOL was Not Ready, which means that the data drive cannot be used.
The command was rejected because the emulation types of the specified P-VOL and S-VOL were
not the same.
EB89
The command was rejected because the emulation types of the specified master journal and the
restore journal were not the same.
EB8A
The command was rejected because the specified pair could not transit the status.EB94
The command was rejected because the specified S-VOL was not mounted on the secondary
system.
EB9F
The command was rejected because the specified S-VOL was not mounted on the secondary
system.
EBA0
The command was rejected because the volume specified for the secondary volume was in either
one of the following status.
EBA7
Increasing the capacity by Thin Provisioning Z.
Releasing the page of Thin Provisioning Z.
Initializing the pool of Thin Provisioning Z.
The command was rejected because the license capacity of the Data Retention in the secondary
system exceeds the setting value. Please check the license capacity setting for Data Retention in
the secondary system.
EBAF
The command was rejected because the specified Cnt Ac-J Z S-VOL was used by either Business
Copy Z or Compatible FlashCopy.
EBC6
The command was rejected because the journal restore operation is in progress in the Cnt Ac-J
Z pair through another mirror ID.
EBCA
If the Cnt Ac-J Z pair with another mirror ID is in Suspending status, re-issue the request when
the pair status is changed to the Suspend status.
If the Cnt Ac-J Z pair with another mirror ID is in the Duplex status, reissue the request after
awhile.
The command was rejected because un-updated differential data exists in the specified S-VOL.EBCE
The Cnt Ac-J Z Pairresync (journal resync mode that forcibly copies all data) was received because
of the Cnt Ac-J Z Pairresync (delta resync) failed. The command was rejected because the Cnt
Ac-J Z pair was not in HOLD status.
EBCF
The command was rejected because the desired capacity exceeded the charging capacity of
the secondary system's Continuous Access Synchronous Z. Check the license capacity as well
as the related program product.
EBD9
The command was rejected because the desired capacity exceeded the charging capacity of
the secondary system's Cnt Ac-J Z. Check the license capacity as well as the related program
product.
EBDB
128 Cnt Ac-J Z troubleshooting