PCI Error Handling Product Note, 2nd Edition, April 2006
Table Of Contents
- Legal Notices
- Publishing History
- Conventions
- PCI Error Handling Product Note
- What is PCI Error Handling?
- Accessing and Installing the PCI Error Handling Feature
- PCI Error Handling Support Matrix
- New Error Messages for PCI Error Handling
- How to Online Recover from a PCI Error
- PCI Error Handling Documentation
- Known Problems
- Removing the PCI Error Handling Feature
- Terms and Definitions

PCI Error Handling Product Note
New Error Messages for PCI Error Handling
Chapter
15
-------------------100BT/Gigabit Ethernet LAN/9000 Networking---------------@#%
Fri Dec 02 PST 2005 11:27:44.753351 DISASTER Subsys:IGELAN Loc:00000
<1004> 1000Base-T in path 1/0/8/1/0/6/1
Is being suspended due to a PCI Error.
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
New iether Driver Error Messages
There are 3 new error messages for the iether driver (IPF Gigabit Ethernet - networking) that will appear in
the console log as illustrated in the following examples:
-------------------100BT/Gigabit Ethernet LAN/9000 Networking---------------@#%
Fri Dec 02 PST 2005 11:27:44.700477 DISASTER Subsys:IETHER Loc:00000
<1002> 1000Base-T in path 1/0/8/1/0/6/1
Was moved to DEAD state due to a PCI error.
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
-------------------100BT/Gigabit Ethernet LAN/9000 Networking---------------@#%
Fri Dec 02 PST 2005 11:27:44.700477 DISASTER Subsys:IETHER Loc:00000
<1003> 1000Base-T in path 1/0/8/1/0/6/1
Resume failed due to a PCI error.
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
-------------------100BT/Gigabit Ethernet LAN/9000 Networking---------------@#%
Fri Dec 02 PST 2005 11:27:44.753351 DISASTER Subsys:IETHER Loc:00000
<1004> 1000Base-T in path 1/0/8/1/0/6/1
Is being suspended due to a PCI Error.
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
New fcd Driver Error Messages
There 6 new error messages for the fcd driver (2-Gigabit 2 port and 4-Gigabit 1 port FibreChannel - mass
storage) that will be logged in syslog as illustrated in the following example(s):
1/0/10/1/0: Fibre Channel Driver has detected a Fatal PCI Error.
1/0/10/1/0: Fibre Channel Driver Received Suspend Request.
1/0/10/1/0: Fibre Channel Driver has been Successfully Suspended.
1/0/10/1/1: Fibre Channel Driver Received Suspend Request.
1/0/10/1/1: Fibre Channel Driver has detected a Fatal PCI Error.
1/0/10/1/1: Fibre Channel Driver has been Successfully Suspended.