PCI Error Handling Product Note 3rd Edition

NOTE: The sysrev command output on some systems includes extra zeros in the system
firmware version number. These zeros can be ignored. For example, 3.88 and 3.088 on HP
Integrity systems are the same firmware version, also 23.1 and 23.001 on HP 9000 systems
represent the same firmware version.
3. The system firmware is the main component of the firmware recipe required to support PCI
Error Handling. If you do not have the minimum system firmware version listed in the PCI
Error Handling Support Matrix (or a later version), you do not have a firmware recipe that
supports PCI Error Handling installed on your system. Contact your HP representative for
assistance on accessing and installing a firmware recipe that supports the PCI Error Handling
feature. If you have the supported system firmware version (or later) installed on your
system, you are ready to install PCI Error Handling from the Application Release (AR)
media.
For information about installing the PCI Error Handling product from the AR media, see:
http://www.docs.hp.com/en/5992-1978/5992-1978.pdf
under Chapter 7, Installing HP Applications and Patches.
NOTE: In addition to installing the PCIErrorHandling bundle, the btlan, igelan, and iether
drivers require patches to enable PCI Error Handling. Also, the latest version of the fcd and mpt
driver must be installed to enable PCI Error Handling.The patch required for the btlan driver is
included with the PCIErrorHandling bundle. The patches required for the igelan and iether
drivers must be downloaded and installed separately from the IT Resource Center at
http://www.itrc.hp.com.
— The iether driver requires patch PHNE 32199 or later.
— The igelan driver requires patch PHNE 34037 or later.
The latest version of the fcd driver (FibrChanl-01 bundle, version B.11.23.0401, or later) must be
downloaded and installed from the Software Depot at http://h20293.www2.hp.com.
The latest version of the mpt driver (scsiU320-00 bundle, version B.11.23.0606, or later) must be
downloaded and installed from the Software Depot at http://h20293.www2.hp.com.
Installing PCI Error Handling from the Software Depot
To install PCI Error Handling from the Software Depot:
1. Go to the HP Software Depot at http://h20293.www2.hp.com
2. Select “Enhancement releases and patch bundles”
3. Select HP-UX Software Pack (Optional HP-UX 11i v2 Core Enhancements)
4. Follow the instructions to download and install PCI Error Handling
10 PCI Error Handling Product Note