AH303A PCIe SC44Ge SAS Host Bus Adapter for Integrity Servers Support Guide, September 2009

To return to the Advanced Adapter Properties screen, press Esc.
PHY Properties Screen
To access the PHY Properties screen, highlight the PHY Properties field on the Advanced adapter
Properties Screen and press Enter. A screen similar to the following appears:
Use the PHY Properties screen to view and modify PHY settings.
Information fields on the PHY Properties screen are as follows:
PHY Indicates the active PHY number.
SAS Port Indicates the associated SAS Port (0 to N) as configured on this
adapter.
Link Status Indicates the PHY link status. Possible values are:
Enabled, Unknown Link Rate
PHY Disabled
Enabled, negotiation failed
Enabled, SATA OOB Complete
Enabled, 1.5 Gb/s
Enabled, 3.0 Gb/s
Discovery Status A 32 bit hexadecimal that indicates the discovery status for the
PHY or expander. Possible values:
Discovery completed successfully - 0x00000000
Loop Detected - 0x00000001
Unaddressable device exists- 0x00000002
Multiple Ports - 0x00000004
Expander Error - 0x00000008
SMP Timeout - 0x00000010
Out of route entries - 0x00000020
SMP Response Index Does Not Exist - 0x00000040
SMP Response Function Failed - 0x00000080
SMP CRC error - 0x00000100
32 Configuring the Adapter Offline