H3C S7500 Series Ethernet Switches Command Manual

Table Of Contents
Command Manual – ACL
H3C S7500 Series Ethernet Switches Chapter 1
ACL Commands
1-9
Description
Use the display time-range command to view the configuration and status of the
current time range. For an active time range, the status is displayed as active; for an
inactive time range, the status is displayed as inactive.
Note that there is a delay (about 1 minute) when the system updates the ACL status,
and the display time-range command displays the status of a time range according to
the current time. Therefore, sometimes you may find that a time range is active by
using the display time-range command, while the ACL referencing the time range is
not activated. This is natural.
Related commands: time-range.
Examples
# Display all time ranges.
<H3C> display time-range all
Current time is 14:36:36 4-3-2003 Thursday
Time-range : hhy ( Inactive )
from 08:30 2-5-2005 to 18:00 2-19-2005
Time-range : hhy1 ( Inactive )
from 08:30 2-5-2003 to 18:00 2-19-2003
Table 1-2 Description on the fields of the display time-range command
Field Description
Current time is 14:36:36 4-3-2003
Thursday
System time
Time-range : hhy ( Inactive )
from 08:30 2-5-2005 to 18:00 2-19-2005
Time range hhy. Inactive indicates that
this time range is currently in the inactive
state (while Active indicates that the
time range is in the active state), and the
time range is from 8:30 February 5, 2005
to 18:00 February 19, 2005.
# Display the time range named tm1.
<H3C> display time-range tm1
Current time is 14:37:31 4-3-2003 Thursday
Time-range : tm1 ( Inactive )
from 08:30 2-5-2005 to 18:00 2-19-2005