HP 10500 Switch Series - HP 10500-CMW710-R2105P05 Release Notes
6
Restrictions and cautions
1. The software version does not support LSU1SUPA0 engine module (JC614A/JG375A), and
LSU1SUPA0 engine module (JC614A/JG375A) should use 10500 1xxx series software version.
2. It takes more than half an hour to collect diagnostic information when the IRF has many
configuration parameters.
3. The hp 10500 product family supports four IRF members. There are several setup and
configuration limitation, please check the Command Line Manual and Operation Manual for
detail.
4. If you enable multicast ARP and connect the device to an NLB server through an aggregate
interface, any port that receives client traffic must not reside on the same card as any member port
of the aggregate interface.
5. The default switch-mode of EA/EB cards is mix-bridging-routing. It is normal that the first time you
insert an EA/EB card into the chassis, the card automatically reboots once or twice and takes
about 10 to 20 minutes to start up. If you set the card in normal mode, the standard startup process
will apply.
6. NTP multicast mode only supports multicast addresses in 224.0.1.0/24.
7. SC cards do not support MPLS and cannot use the extended forwarding capabilities of other
cards.
Open problems and workarounds
LSD078632
Symptom: If a card that uses bootware 202 or earlier is inserted into slot 13 of an S10512, the card
cannot boot up.
Condition: This symptom occurs if the card in slot 13 of an S10512 uses bootware 202 or earlier.
Workaround: Insert a card that uses bootware 202 or earlier into one of the first 11 slots.
LSD068672
Symptom: The IRF fabric may split.
Condition: Reboot an IRF fabric comprised of four switches. If the switches are not synchronously
rebooted.
Workaround: Make sure the switches have similar card configurations, can back up each other,
and are rebooted at the same time. If the IRF fabric splits, reboot the smallest IRF system so the
switches can join the system to re-form a 4-chassis fabric.
LSV7D001930
Symptom: After an incompatible ISSU on an IRF fabric that is the root of the TRILL multicast
distribution tree, the TRILL nickname (bridge MAC address) of the IRF fabric is changed but the root
name is not changed to the new name, resulting in a 20 -minute interruption of multicast traffic.
Condition: This symptom occurs after an incompatible ISSU on an IRF fabric that is the root of the
TRILL multicast distribution tree. After the ISSU, the TRILL nickname (bridge MAC address) of the IRF
fabric is changed, but the root name of the TRILL multicast distribution tree is not changed to the new
name.